Download IconPrint Icon

BayCom® Telecommunication cables

A-2YF(L)2Y ... StIII

...x2x0,8 acc. to DIN VDE 0816


KT133_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung36-Längswasserdicht38-Querwasserdicht40-Geschirmt20-UV-beständig53-Verlegung -20

optional

Trinkwassergeeignet optionalHybrid optional

Standards

DIN VDE 0816-part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.8
Conductor resistance (pair of cores) Ω/km ≤ 73.2
Insulation resistance GΩxkm ≥ 1.5
Mutual capacitance nF/km at 800 Hz ≤ 55
Capacitive couplings pF/km at 800 Hz
k1 (98%/100% of all values)
k9-12 (98%/100% of all values)


≤ 1333/2666
≤ 333/1000

Alternating voltage test 50 Hz
core-core V
core-screen V

500
2000
Operating voltage V ≤ 225
Cable temperature ºC
during laying
during operation

-20 to +50
-40 to +70

Application

As connection cable in subscriber networks and private branch exchanges, for telephony and signal transmission. Laying in the ground and in cable ducts, as well as threading into cable conduits. The cables are VDE approved.

BayCom* Telecommunication cables are used to transmit high-frequency signals as in xDSL or PCM systems. BayCom* cables are backward compatible and will meet all the requirements of the specification. Due to the production with high quality machines with tight tolerances additional RF characteristics can be guaranteed. These are measured for each drum and documented by an included factory certificate.

For further product information on BayCom®* contact our sales department.

Type Designation Codes

2Y core insulation made of polyethylene (PE)
A outdoor cable
F cable core filled with petroleum jelly, longitudinally watertight
(L) 2Y laminated sheath, transversally watertight
St III starquad in the local cable
BD stranded in bundles
   

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-2YF(L)2Y 50x2x0,8 St III BD


Print Icon

BayCom® Telecommunication cables

A-2YF(L)2Y ... StIII

...x2x0,8 acc. to DIN VDE 0816

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YF(L)2Y     2x2x0,8 StIIIBd 5450000 20 9 90 20 40 80
A-2YF(L)2Y     4x2x0,8 StIIIBd 5449900 40 12 130 35 45 90
A-2YF(L)2Y     6x2x0,8 StIIIBd 5450100 60 13 180 40 50 100
A-2YF(L)2Y    10x2x0,8 StIIIBd 5450200 101 16 260 70 60 120
A-2YF(L)2Y    20x2x0,8 StIIIBd 5450300 201 20 440 110 80 160
A-2YF(L)2Y    30x2x0,8 StIIIBd 5450400 302 22 600 150 85 170
A-2YF(L)2Y    40x2x0,8 StIIIBd 5450500 402 25 780 180 90 190
A-2YF(L)2Y    50x2x0,8 StIIIBd 5450600 503 28 950 230 105 210
A-2YF(L)2Y    70x2x0,8 StIIIBd 5450800 704 31 1235 230 130 260
A-2YF(L)2Y   100x2x0,8 StIIIBd 5450900 1005 37 1740 460 140 280
A-2YF(L)2Y   150x2x0,8 StIIIBd 5451000 1508 43 2510 390 180 360
A-2YF(L)2Y   200x2x0,8 StIIIBd 5451200 2011 51 3430 440 215 430
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.