BayCom® FO outdoor cables, metal-free, with armouring/rodent protection
A-DQ(ZN)b2Y
light outdoor cable acc. to DIN VDE and Bayka standard











Standards
DIN VDE 0888-114, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.
The cables are in compliance with RoHS Directive EU 2011/65/EU - RoHS 2.0 and Regulation No. 1907/2006 (REACH).
Technical Data
Single-mode fibre G.652.D (Standard) G.652.D (BayCom *) G.657.A1 |
E9/125 0,36F3,5 0,22H18 E9/125 0,35F3,0 0,21H18 E9/125 0,36F3,5 0,21H18 |
Graded index fibre OM2 OM3 OM4 |
G50/125 2,5B500 0,7F500 G50/125 2,5B1500 0,7F500 G50/125 2,5B3500 0,7F500 |
Colour coding of fibres | acc. to IEC 60304 |
Permissible temperature range °C transport and storage laying operation |
-30 to +70 -5 to +60 -25 to +60 |
Application
Metal-free outdoor cable with non-metallic rodent protection, as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:
-
Light-weight outdoor cable
Easy installation with tight bending radii and easy installation by an optimised cable design with small outer diameter.
The cable is suitable for installation outdoors, in trays and ducts, on cable trays and pipes. For direct laying in the ground and large mechanical loads, additional protective measures must be provided.
The following applies to FO cables acc. to the company standard BayCom LWL01:
- Quality assurance through VDE Certificate/VDE manufacturing report
- 1 rip cord facilitates installation
The following applies additionally for BayCom* FO cables
Improved optical properties compared to standard fibres
Type Designation Codes
A | outdoor cable |
D | loose tube, filled |
Q | cable core dry filled, longitudinally watertight |
(ZN) | non-metallic stress relief elements |
b | non-metallic rodent protection |
2Y | outer sheath made of polyethylene, PE |
Order Example
A-DQ(ZN)b2Y 1x12 E9/125
A-DQ(ZN)b2Y 1x12 E9/125 G.652.D BayCom*
BayCom® FO outdoor cables, metal-free, with armouring/rodent protection
A-DQ(ZN)b2Y
light outdoor cable acc. to DIN VDE and Bayka standard
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.