Download IconPrint Icon

BayCom® FO outdoor cables with metallic armouring

A-DF(ZN)2Y(SR)2Y

FO outdoor cable German Railways DB acc. to DIN VDE and Bayka standard


OT111_A-DF(ZN)2Y(SR)2Y_OT16_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung44-Nagetierschutz36-Längswasserdicht50-Verlegung -5

 


Standards

Acc. to Dlk 1.011.003y.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Type of fibre  E9/125
Field diameter μm  9-10
Sheath diameter μm  125
Attenuation dB/km
at 1310 nm
at 1550 nm
≤ 0.36
≤ 0.23
Chromatic dispersion
ps/[nm x km]
at 1310 +30/-15 nm
at 1550 +30/-70 nm  

≤ 3.5
≤ 18

Permissible temperature range °C

 

transport and storage

-40 to +70

laying

-5 to +50

operation

-30 to +60


 

Application

The FO outdoor cable according to this standard can be laid
- in the ground by pulling into a previously installed HDPE pipe or
- in trays along railway lines.

Use, planning and laying shall be carried out according to the applicable guidelines of the DB AG.
The cables are approved for use in the DB network.

Type Designation Codes

A outdoor cable
D loose tube, filled
F cable core filled with petroleum jelly, longitudinally watertight
(ZN) non-metallic tensile reinforcement
2Y inner sheath made of polyethylene, PE
(SR) corrugated steel tape armourimg
2Y outer sheath made of polyethylene, PE
LG stranded in layers

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DF(ZN)2Y(SR)2Y 12x12 E9/125 0,36F3,5 / 0,23H18 LG

DB vendor no. 00105422,
Framework contract no. 1000/393/92194647


Print Icon

BayCom® FO outdoor cables with metallic armouring

A-DF(ZN)2Y(SR)2Y

FO outdoor cable German Railways DB acc. to DIN VDE and Bayka standard

Product Bayka Order No. Customer Order-No. No. of fibers Outer ∅
approx.
Net weight
approx.
Bending radius one-off Bending radius repeated Max. tensile force Fire load
mm kg/km min. mm min. mm daN MJ/m  
A-DF(ZN)2Y(SR)2Y   6x 2 E9/125  (00652692) 5924110 00652692 12 17 280 300 400 250 6.0
A-DF(ZN)2Y(SR)2Y   6x 4 E9/125  (00635514) 5924120 00635514 24 17 280 300 400 250 6.0
A-DF(ZN)2Y(SR)2Y   4x12 E9/125  (00827007) 5931510 00827007 48 18.5 330 330 450 250 8.0
A-DF(ZN)2Y(SR)2Y   5x12 E9/125  (00635516) 5924900 00635516 60 18.5 330 330 450 250 8.0
A-DF(ZN)2Y(SR)2Y   6x12 E9/125 5924140 72 19.5 370 350 450 250 8.5
A-DF(ZN)2Y(SR)2Y   7x12 E9/125 5924940 84 20 400 350 450 250 8.5
A-DF(ZN)2Y(SR)2Y   8x12 E9/125 5924930 96 20.5 420 350 450 250 11.0
A-DF(ZN)2Y(SR)2Y  12x12 E9/125  (00635519) 5924910 00635519 144 24 570 400 500 350 14.5
Errors and omissions excepted, weights and dimensions are approximate values.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Tensile stress only valid when cable sheath and cable core involved.