Download IconPrint Icon

BayCom® FO outdoor cables, metal-free, with armouring/rodent protection


light outdoor cable acc. to DIN VDE and Bayka standard



08-Trogverlegung04-Rohrverlegung20-UV-beständig44-Nagetierschutz36-Längswasserdicht50-Verlegung -5



DIN VDE 0888-114, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Single-mode fibre
G.652.D (Standard)
G.652.D (BayCom *)

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
E9/125 0,36F3,5 0,21H18
Graded index fibre

G50/125 2,5B500 0,7F500
G50/125 2,5B1500 0,7F500
G50/125 2,5B3500 0,7F500
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage

-30 to +70
-5 to +60
-25 to +60


Metal-free outdoor cable with non-metallic rodent protection, as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:

  • Light-weight outdoor cable
    Easy installation with tight bending radii and easy installation by an optimised cable design with small outer diameter.
    The cable is suitable for installation outdoors, in trays and ducts, on cable trays and pipes. For direct laying in the ground and large mechanical loads, additional protective measures must be provided.

The following applies to FO cables acc. to the company standard BayCom LWL01:

  • Quality assurance through VDE Certificate/VDE manufacturing report
  • 1 rip cord facilitates installation

The following applies additionally for BayCom* FO cables

Improved optical properties compared to standard fibres

Type Designation Codes

A outdoor cable
D loose tube, filled
Q cable core dry filled, longitudinally watertight
(ZN) non-metallic stress relief elements
b non-metallic rodent protection
2Y outer sheath made of polyethylene, PE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DQ(ZN)b2Y 1x12 E9/125
A-DQ(ZN)b2Y 1x12 E9/125 G.652.D BayCom*

Print Icon

BayCom® FO outdoor cables, metal-free, with armouring/rodent protection


light outdoor cable acc. to DIN VDE and Bayka standard

Product Bayka Order No. No. of fibers Outer ∅
Net weight
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DQ(ZN)b2Y        1x 2 E9/125  (ZB) 5800701 2 7 45 170 110 150 1.6
A-DQ(ZN)b2Y        1x 4 E9/125  (ZB) 5800711 4 7 45 170 110 150 1.6
A-DQ(ZN)b2Y        1x 6 E9/125  (ZB) 5800331 6 7 45 170 110 150 1.6
A-DQ(ZN)b2Y        1x 8 E9/125  (ZB) 5800381 8 7 45 170 110 150 1.6
A-DQ(ZN)b2Y        1x10 E9/125  (ZB) 5800721 10 7 45 170 110 150 1.6
A-DQ(ZN)b2Y        1x12 E9/125  (ZB) 5800201 12 7 45 170 110 150 1.6
A-DQ(ZN)b2Y        1x16 E9/125  (ZB) 5800731 16 7 45 150 110 150 1.6
A-DQ(ZN)b2Y        1x24 E9/125  (ZB) 5800741 24 7 45 150 110 150 1.6
The part numbers in the table are for fibers after G.652.D (standard)
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.