BayCom® FO outdoor cables with Al-laminated sheath
A-DF(ZN)(L)2Y
direct burial acc. to DIN VDE and Bayka standard













Standards
DIN VDE 0888-3, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.
The cables are in compliance with RoHS Directive EU 2011/65/EU - RoHS 2.0 and Regulation No. 1907/2006 (REACH).
Technical Data
Single-mode fibre G.652.D (Standard) G.652.D (BayCom *) G.657.A1 |
E9/125 0,36F3,5 0,22H18 E9/125 0,35F3,0 0,21H18 E9/125 0,36F3,5 0,21H18 |
Graded index fibre OM2 OM3 OM4 |
G50/125 2,5B500 0,7F500 G50/125 2,5B1500 0,7F500 G50/125 2,5B3500 0,7F500 |
Colour coding of fibres | acc. to IEC 60304 |
Permissible temperature range °C transport and storage laying operation |
-40 to +70 -10 to +60 -30 to +70 |
Application
FO outdoor cable with laminated sheath as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:
-
Rugged outdoor cable (direct underground installation)
This cable is optimised for underground installation and complies with the long experience of fibre optic and telecommunication cables laid in the ground (VDE 0888, VDE 0816 and similar).
The following applies to FO cables acc. to the company standard BayCom LWL01:
- Quality assurance through VDE Certificate/VDE manufacturing report
- 2 rip cords facilitate installation
The following applies additionally for BayCom* FO cables
Improved optical properties compared to standard fibres
Type Designation Codes
A | outdoor cable |
D | loose tube, filled |
F | cable core filled with petroleum jelly, longitudinally watertight |
(ZN) | non-metallic stress relief elements |
(L)2Y | laminated sheath, transversally watertight |
Order Example
A-DF(ZN)(L)2Y 12x12 E9/125
A-DF(ZN)(L)2Y 12x12 E9/125 G.652.D BayCom*
BayCom® FO outdoor cables with Al-laminated sheath
A-DF(ZN)(L)2Y
direct burial acc. to DIN VDE and Bayka standard
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.