Download IconPrint Icon

BayCom® FO outdoor cables with Al-laminated sheath and Cu cores/pairs/quads

A-DSOF(ZN)(L)2Y
nx... + Cu

direct burial acc. to DIN VDE and Bayka standard


PT362_A-DSF(ZN)(L)2Y_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung20-UV-beständig46-Robust36-Längswasserdicht38-Querwasserdicht51-Verlegung -10

 


Standards

DIN VDE 0888-3, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Single-mode fibre
G.652.D (Standard)
G.652.D (BayCom *)
G.657.A1

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
E9/125 0,36F3,5 0,21H18
Graded index fibre
OM2
OM3
OM4

G50/125 2,5B500 0,7F500
G50/125 2,5B1500 0,7F500
G50/125 2,5B3500 0,7F500
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage
laying
operation


-40 to +70
-10 to +60
-30 to +70

Application

FO outdoor cable with laminated sheath and copper pairs/quads as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:

  • Rugged outdoor cable (direct underground installation)
    This cable is optimised for underground installation and complies with the long experience of fibre optic and telecommunication cables laid in the ground (VDE 0888, VDE 0816 and similar).

The following applies to FO cables acc. to the company standard BayCom LWL01:

  • Quality assurance through VDE Certificate/VDE manufacturing report
  • 2 rip cords facilitate installation

The following applies additionally for BayCom* FO cables

Improved optical properties compared to standard fibres

Type Designation Codes

A outdoor cable
D loose tube, filled
S metallic stranding element in the cable core (e.g. Cu pair)
OF cable core with special filling material, longitudinally watertight
(ZN) non-metallic stress relief elements
(L)2Y laminated sheath made of PE, transversally watertight

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DSOF(ZN)(L)2Y 12x12 E9/125 + CU
A-DSOF(ZN)(L)2Y 12x12 E9/125 + CU G.652.D BayCom*


Print Icon

BayCom® FO outdoor cables with Al-laminated sheath and Cu cores/pairs/quads

A-DSOF(ZN)(L)2Y
nx... + Cu

direct burial acc. to DIN VDE and Bayka standard

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DSOF(ZN)(L)2Y    1x 2 E9/125 + CU2Y 1x2x0,6 5831710 2 11 105 150 180 230 3.5
A-DSOF(ZN)(L)2Y    2x 2 E9/125 + CU2Y 1x2x0,6 5831720 4 11 105 150 180 230 3.5
A-DSOF(ZN)(L)2Y    4x 2 E9/125 + CU2Y 1x2x0,6 5831730 8 11 110 150 180 230 3.5
A-DSOF(ZN)(L)2Y    6x 2 E9/125 + CU2Y 1x2x0,6 5831740 12 13 135 200 190 260 4.5
A-DSOF(ZN)(L)2Y    6x 4 E9/125 + CU2Y 1x2x0,6 5831750 24 13 135 220 190 260 4.5
A-DSOF(ZN)(L)2Y    6x 6 E9/125 + CU2Y 1x2x0,6 5831760 36 13 135 200 190 260 4.5
A-DSOF(ZN)(L)2Y    4x12 E9/125 + CU2Y 1x2x0,6 5831770 48 12 125 200 190 250 4.0
A-DSOF(ZN)(L)2Y    5x12 E9/125 + CU2Y 1x2x0,6 5831780 60 13 140 200 200 260 4.5
A-DSOF(ZN)(L)2Y    6x12 E9/125 + CU2Y 1x2x0,6 5831790 72 13 155 250 210 280 5.0
The part numbers in the table are for fibers after G.652.D (standard)
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.