Print Icon

BayCom® Telecommunication cables

A-02Y(L)2Y ... StVII
A-02YSF(L)2Y ... StVII
BayCom**

A-02Y(L)2Y ...x2x0,8 unfilled acc. to Bayka standard BayCom**


KT174_en
Telekom_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung38-Querwasserdicht40-Geschirmt20-UV-beständig53-Verlegung -20

 


Standards

Bayka company standard BayCom**, based on Deutsche Telekom AG TS 0031, part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.8
Conductor resistance Ω/km 69.0±4.2
Insulation resistance GΩxkm ≥10
Mutual capacitance nF/km (at 800 Hz) ≤41
Capacitive couplings pF/km (at 800 Hz)  
K1 ≤380
K9-12 ≤150
Characteristic impedance Ω 135±15
HF properties
Frequency MHz
 
1
 
4
 
16
Wave attenuation dB/km ≤ 12 ≤ 25 ≤ 52
NEXT dB (80%/100% of all values)
within a bundle, within a quad and quad/quad
 
 
≥ 49/45
 
 
≥ 40/36
 
 
≥ 31/27
ELFEXT dB/km (80%/100% of all values)  
≥ 47/43
   
*) Attenuation at 4 and 16 MHz, NEXT at 1 and 16 MHz acc. to gem. type approval test
Temperature ranges
during laying °C
before and after laying °C
 
-20 to +50
-20 to +70

Application

As connection cable in subscriber networks and private branch exchanges, for telephony and for transmitting higher-frequency signals in the case of xDSL or PCM systems, in particular in the case of very high requirements on the HF properties, such as when connecting distant collocation centres and multifunction housings.
BayCom® ** communication cables are suitable for VDSL systems.

Type Designation Codes

A outdoor cable
02Y core insulation made of cell PE
(L)2Y laminated sheath, transversally watertight
StVII starquad, suitable for HF
BD stranded in bundles

Special Designs

Design according to national and international standards
Design according to customer specifications

Order Example

A-02Y(L)2Y 100x2x0,8 StVII Bd BayCom**


Print Icon

BayCom® Telecommunication cables

A-02Y(L)2Y ... StVII
A-02YSF(L)2Y ... StVII
BayCom**

A-02Y(L)2Y ...x2x0,8 unfilled acc. to Bayka standard BayCom**

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Bending radius one-off Bending radius repeated Max. tensile force
kg/km mm kg/km min. mm min. mm daN  
A-02Y(L)2Y    10x2x0,8 StVIIBd BayCom** 5455610 101 14 200 55 110 70
A-02Y(L)2Y    20x2x0,8 StVIIBd BayCom** 5455620 201 17 330 75 130 110
A-02Y(L)2Y    30x2x0,8 StVIIBd BayCom** 5455630 302 21 460 80 160 150
A-02Y(L)2Y    50x2x0,8 StVIIBd BayCom** 5455650 503 25 730 100 200 250
A-02Y(L)2Y   100x2x0,8 StVIIBd BayCom** 5455705 1005 33 1350 130 260 460
A-02Y(L)2Y   150x2x0,8 StVIIBd BayCom** 5455725 1508 39 1950 160 320 650
A-02Y(L)2Y   200x2x0,8 StVIIBd BayCom** 5455720 2011 46 2580 175 350 850
A-02Y(L)2Y   300x2x0,8 StVIIBd BayCom** 5455730 3016 55.5 3800 210 420 1150
A-02Y(L)2Y   400x2x0,8 StVIIBd BayCom** 5455740 4022 63 4900 240 480 1450
A-02Y(L)2Y   500x2x0,8 StVIIBd BayCom** 5455750 5027 68 6100 265 530 1700
A-02Y(L)2Y   600x2x0,8 StVIIBd BayCom** 5455760 6032 75 7300 290 580 1850
A-02Y(L)2Y   800x2x0,8 StVIIBd BayCom** 5455780 8043 86 9440 330 660 2150
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.