Print Icon

BayCom® Telecommunication cables

A-02Y(L)2Y ... StVII
A-02YSF(L)2Y ... StVII
BayCom**

A-02YSF(L)2Y ...x2x0,8 filled acc. to Bayka standard BayCom**


KT175_en
Telekom_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung36-Längswasserdicht38-Querwasserdicht40-Geschirmt20-UV-beständig53-Verlegung -20

optional

Trinkwassergeeignet optionalHybrid optional

Standards

Bayka company standard BayCom**, based on Deutsche Telekom AG TS 0031, part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.8
Conductor resistance Ω/km 69.0±4.2
Insulation resistance GΩxkm ≥3
Mutual capacitance nF/km (at 800 Hz) ≤42
Capacitive couplings pF/km (at 800 Hz)  
K1 ≤380
K9-12 ≤150
Characteristic impedance Ω 135±15
HF properties
Frequency MHz
 
1
 
4
 
16
Wave attenuation dB/km ≤ 11 ≤ 21 ≤ 46
NEXT dB (80%/100% of all values)
within a bundle, within a quad and quad/quad
 
 
≥ 49/45
 
 
≥ 40/36
 
 
≥ 31/27
ELFEXT dB/km (80%/100% of all values)  
≥ 47/43
   
*) Attenuation at 4 and 16 MHz, NEXT at 1 and 16 MHz acc. to gem. type approval test
Temperature ranges
during laying °C
before and after laying °C
 
-20 to +50
-20 to +70

Application

As connection cable in subscriber networks and private branch exchanges, for telephony and for transmitting higher-frequency signals in the case of xDSL or PCM systems, in particular in the case of very high requirements on the HF properties, such as when connecting distant collocation centres and multifunction housings.
BayCom® ** communication cables are suitable for VDSL systems.

Type Designation Codes

A outdoor cable
02YS core insulation made from cell PE with outer polyolefin layer
F cable core filled with petroleum jelly, longitudinally watertight
(L)2Y laminated sheath, transversally watertight
StVII starquad, suitable for HF
BD stranded in bundles

Special Designs

Design according to national and international standards
Design according to customer specifications

Order Example

A-02YSF(L)2Y 100x2x0,8 StVII Bd BayCom**


Print Icon

BayCom® Telecommunication cables

A-02Y(L)2Y ... StVII
A-02YSF(L)2Y ... StVII
BayCom**

A-02YSF(L)2Y ...x2x0,8 filled acc. to Bayka standard BayCom**

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-02YSF(L)2Y   6x2x0,8 StVIIBd  BayCom** 5475704 60 14 170 40 50 100
A-02YSF(L)2Y  10x2x0,8 StVIIBd  BayCom** 5475706 101 15.5 260 70 50 100
A-02YSF(L)2Y  20x2x0,8 StVIIBd  BayCom** 5475707 201 21 450 110 75 150
A-02YSF(L)2Y  30x2x0,8 StVIIBd  BayCom** 5475708 302 24 630 150 100 200
A-02YSF(L)2Y  40x2x0,8 StVIIBd  BayCom** 5475711 402 27 810 180 110 220
A-02YSF(L)2Y  50x2x0,8 StVIIBd  BayCom** 5475715 503 28.5 950 230 120 240
A-02YSF(L)2Y 100x2x0,8 StVIIBd  BayCom** 5475725 1005 38 1800 460 150 300
A-02YSF(L)2Y 150x2x0,8 StVIIBd  BayCom** 5475728 1508 46.5 2860 680 200 400
A-02YSF(L)2Y 200x2x0,8 StVIIBd  BayCom** 5475730 2011 54 3540 850 200 400
A-02YSF(L)2Y 300x2x0,8 StVIIBd  BayCom** 5475735 3016 64 5200 1150 280 560
A-02YSF(L)2Y 400x2x0,8 StVIIBd  BayCom** 5475740 4022 81 6950 1450 350 700
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.