Print Icon

BayCom® FO outdoor cables

A-DF(ZN)2Y

FO outdoor cable German Railways DB according to DB Dlk 1.011.003y

Print Icon

BayCom® FO outdoor cables

A-DF(ZN)2Y

FO outdoor cable German Railways DB according to DB Dlk 1.011.003y

Product Bayka Order No. Customer Order-No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DF(ZN)2Y         6x 2 E9/125 5923500 12 12 125 250 300 400 3.4
A-DF(ZN)2Y         6x 4 E9/125 5923700 24 12 125 250 300 400 3.4
A-DF(ZN)2Y         4x12 E9/125 5924230 48 13.5 165 250 330 450 4.2
A-DF(ZN)2Y         5x12 E9/125 5962300 60 13 120 250 330 450 4.2
A-DF(ZN)2Y         6x12 E9/125 5923100 72 14.5 170 250 350 450 4.5
A-DF(ZN)2Y         7x12 E9/125 5932820 84 15 185 250 350 450 5.5
A-DF(ZN)2Y         8x12 E9/125 5932810 96 16.5 205 250 350 450 6.0
A-DF(ZN)2Y        12x12 E9/125 5923900 144 20 310 350 400 500 9.5
A-DF(ZN)2Y        16x12 E9/125 5932930 192 24 450 450 450 600 13.5
Errors and omissions excepted, weights and dimensions are approximate values.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Tensile stress only valid when cable sheath and cable core involved.