Download IconPrint Icon

BayCom® FO indoor cables (FRNC/LSOH)

I-D(ZN)H Arcor TNP07

Fiber optic indoor cable E9/125 acc. to Arcor TNP07 (DB AG)


OT711_I-D(ZN)H_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

16-Inhouse23-Halogenfrei24-Flammwidrig26-Raucharm

 


Standards

Acc. to Arcor TNP 07.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Type of fibre  E9/125
Field diameter μm   8.6-9.5
Sheath diameter μm  125
Attenuation dB/km
at 1310 nm
at 1550 nm
≤ 0.40
≤ 0.30
Chromatic dispersion ps/[nm x km]
at 1310 +60/-30 nm
at 1550 +30/-70 nm
at 1550 nm

≤ 5
≤ 21
≤ 19

Permissible temperature range °C

 

transport and storage

-25 to +70

laying

-5 to +50

operation

-5 to +70


 

Application

FO indoor cable for installation in buildings

  • as continuation of outdoor cables up to the cable termination equipment, and
  • from cable termination equipment to distributors (in special cases)
  • for in-house networks (multi-mode with graded index fibres)

This indoor cable is designed for laying on cable grids, grid routes, cable channels and raised floors. It is not designed for laying in the ground nor for outdoor installations.

FO indoor cables are available with central loose tube or with stranded loose tubes.

Type Designation Codes

I indoor cable
D loose tube, filled
(ZN) non-metallic tensile reinforcement
H outer sheath made of halogen-free, flame retardant copolymer

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

I-D(ZN)H 6x12 E9/125 Arcor TNP 07

DB-Kreditoren-Nr. 00105422,
Rahmenvertragsnr. 1000/393/92194647


Print Icon

BayCom® FO indoor cables (FRNC/LSOH)

I-D(ZN)H Arcor TNP07

Fiber optic indoor cable E9/125 acc. to Arcor TNP07 (DB AG)

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
I-D(ZN)H           1x 4 E9/125  (M-GR / ZB) 5913200 4 6 42 45 50 100 0.8
I-D(ZN)H           1x12 E9/125  (M-GR / ZB) 5913500 12 6 42 40 50 100 0.8
I-D(ZN)H           6x 4 E9/125 (M-GR) 5913400 24 9 80 100 100 200 1.6
I-D(ZN)H           4x12 E9/125 (M-GR) 5913700 48 11 115 100 100 200 2.5
I-D(ZN)H           5x12 E9/125 (M-GR) 5913800 60 11 115 100 100 200 2.5
I-D(ZN)H           6x12 E9/125  (M-GR) 5913600 72 12 132 100 100 200 2.9
Errors and omissions excepted, weights and dimensions are approximate values.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Tensile stress only valid when cable sheath and cable core involved.
Other designs, fitted lengths and larger delivery lengths on request.