Print Icon

BayCom® Railway telecommunication cables

A-02YSF(L)2Y ... StIII
AJ-02YSF(L)2Y ... StIII

AJ ...x2x0,8 acc. to DB Dlk 1.013.151y


KT163_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung36-Längswasserdicht38-Querwasserdicht40-Geschirmt20-UV-beständig53-Verlegung -20

optional

Trinkwassergeeignet optionalHybrid optional

Standards

Dlk 1.013.151y and/or DIN VDE 0816-part 1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.8
Conductor resistance (pair of cores) Ω/km ≤73.2
Insulation resistance GΩxkm ≥ 1.5
Mutual capacitance at 800Hz nF/km ≤ 42
Capacitive couplings pF/km at 800 Hz
k1 (98%/100% of all values)
k9-12 (98%/100% of all values)

≤ 1333/2666
≤ 333/1000
Operating voltage V ≤ 225
Alternating voltage test 50 Hz
core-core Veff
core-screen Veff
 
500
2000
Temperature ranges
during laying, installing °C
before and after laying, installing °C

-20 to +50
  to+70

Application

As induction-protected connection cable in subscriber networks and private branch exchanges, for telephony and data transfer. Suitable for laying in the ground and in cable ducts, as well as for threading into cable conduits.

The cables are approved by VDE (certificate with production monitoring) and released for the use in the area of operation of Deutsche Bahn AG.

Type Designation Codes

A outdoor cable
02YS conductor insulation made from cell PE with outer polyolefin layer
F cable core filled with petroleum jelly, longitudinally watertight
(L)2Y laminated sheath, transversally watertight
D inductive protection made of copper wires
B steel tape armouring
2Y outer sheath made of PE, black
St III starquad in the local cable
Bd stranded in bundles
(H42) Mutual capacitance max value 42 nF/km

Special Designs

Design according to national and international standards
Design according to customer specifications

Order Example

AJ-02YSF(L)2YDB2Y 10x2x0,6 STIII Bd (H42)


Print Icon

BayCom® Railway telecommunication cables

A-02YSF(L)2Y ... StIII
AJ-02YSF(L)2Y ... StIII

AJ ...x2x0,8 acc. to DB Dlk 1.013.151y

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
AJ-02YSF(L)2YDB2Y     10x2x0,8 StIII Bd (H 42)     (00174223) 5493000 429 24.5 1130 265 125 250
AJ-02YSF(L)2YDB2Y     20x2x0,8 StIII Bd (H 42)     (00174224) 5493200 631 29 1570 370 125 250
AJ-02YSF(L)2YDB2Y     30x2x0,8 StIII Bd (H 42)     (00174225) 5465500 859 33 1990 480 150 300
AJ-02YSF(L)2YDB2Y     40x2x0,8 StIII Bd (H 42)     (00174226) 5465600 1095 36.5 2440 590 150 300
AJ-02YSF(L)2YDB2Y     50x2x0,8 StIII Bd (H 42)     (00174227) 5465700 1228 39 2730 600 175 350
AJ-02YSF(L)2YDB2Y     70x2x0,8 StIII Bd (H 42)     (00174228) 5466400 1609 45.5 3900 760 175 350
AJ-02YSF(L)2YDB2Y    100x2x0,8 StIII Bd (H 42)     (00174229) 5466000 2176 51 4910 955 200 400
AJ-02YSF(L)2YDB2Y    150x2x0,8 StIII Bd (H 42)     (00174230) 5466600 2679 60.5 6220 1085 250 500
AJ-02YSF(L)2YDB2Y    200x2x0,8 StIII Bd (H 42)     (00174231) 5468000 3287 68 7530 1205 275 550
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.