Print Icon

BayCom® Telecommunication cables, direct-buried cables

AJ-02YSTF(L)2YDB2Y

with inductive protection acc. to Arcor TNP02 (DB AG)


LT103_AJ-02YSTF(L)2YDB2Y_de
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung36-Längswasserdicht38-Querwasserdicht40-Geschirmt44-Nagetierschutz46-Robust50-Verlegung -5

 


Standards

Arcor TNP 02, Bayka company standard BayCom®

Technical Data

(Values for BayCom®★ in parentheses)

Conductor diameter mm 0.9 1.4
Conductor resistance (pair of cores) Ω/km ≤ 56.6 ≤ 23.4
Resistance difference Ω/km
(for conductors 0.9: BayCom®★: max. 20 % of the values ≤ 0.25)

≤ 0.30 (0.15)

≤ 0.20 (0.18)
Insulation resistance GΩxkm ≥ 10 ≥ 10
Mutual capacitance nF/km
(at 800 Hz)
(for 1.4 mm conductor diameter: 15 % of all value ≤ 40.3)

≤ 34

≤ 36
Capacitive coupling k1 pF
(at 800 Hz)
100 % of all values
80 % of all values


≤ 400 (300)
≤ 110


≤ 400 (300)
≤ 110
Capacitive coupling k9-12 pF
(at 800 Hz)
100 % of all values
80 % of all values


≤ 400 (250)
≤ 110


≤ 400 (250)
≤ 110
Wave attenuation dB/km
(at 1 MHz)
100 % of all values
80 % of all values


≤ 9.0 (8.5)
≤ 8.5
 
Near-end crosstalk attenuation NEXT dB
(HF quad at 1 MHz)
within the quad
quad/quad within the group
quad/quad between the groups
for 2 HF quads
for 4 HF quads
for 6 HF quads
for 8 HF quads



≥ 45 (48)
≥ 55

≥ 62
≥ 64
≥ 66
≥ 68
 
LF quads dB
(at 1 MHz, BayCom®★ only)
within the quad
quad/quad within the group


≥ 45
≥ 40
 
Far-end crosstalk attenuation ELFEXT dB/km
(at 1 MHz)
within the HF quad
within the LF quad (BayCom®★ only)



≥ 45
≥ 45
 

Application

For general cabling at railway tracks. In the new construction case, as replacement types for the paper-insulated cables with F, TF, TFS and coax construction elements according to Dlk 1.01.106 of Deutsche Bahn AG. For laying in the ground, in pipe conduits and trough channels in accordance with the applicable regulations.
All trunk lines of the cables can be interconnected surge-free with trunk lines of the same nominal conductor diameter of the cables according to Dlk 1.01.106 (paper-metal sheath cables of the existing network).

BayCom ® ★ long-distance cables offer increased interference resistance and improved HF and LF properties compared to cables according to Arcor TNP 02.

Type Designation Codes

AJ outdoor cable with inductive protection
02YS conductor insulation made from cell PE with outer polyolefin layer (foam skin)
TF cable core dry filled, longitudinally watertight
(L)2Y laminated sheath, transversally watertight
D inductive protection made of copper wires
B steel tape armouring
2Y outer sheath made of PE
STI starquad in track cable quality (increased electrical properties)
LG stranded in layers

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

AJ-02YSTF(L)2YDB2Y 1x4x1,4 / 7x4x0,9 STI A ARCOR TNP 02


Print Icon

BayCom® Telecommunication cables, direct-buried cables

AJ-02YSTF(L)2YDB2Y

with inductive protection acc. to Arcor TNP02 (DB AG)

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
AJ-02YSTF(L)2YDB2Y    10x4x0,9 STI  A  ARCOR TNP 02 5208200 450 37 1730 210 275 370
AJ-02YSTF(L)2YDB2Y    16x4x0,9 STI  A  ARCOR TNP 02 5218200 615 41 2110 276 305 410
AJ-02YSTF(L)2YDB2Y    19x4x0,9 STI  A  ARCOR TNP 02 5219200 691 43 2260 306 320 430
AJ-02YSTF(L)2YDB2Y    24x4x0,9 STI  A  ARCOR TNP 02 5223200 857 49 2750 353 365 490
AJ-02YSTF(L)2YDB2Y    30x4x0,9 STI  A  ARCOR TNP 02 5227200 1022 52 3060 410 390 520
AJ-02YSTF(L)2YDB2Y   1x4x1,4 /  7x4x0,9 STI  A  ARCOR TNP 02 5206200 410 34 1490 213 255 340
AJ-02YSTF(L)2YDB2Y   2x4x1,4 / 11x4x0,9 STI  A  ARCOR TNP 02 5209200 624 42 2030 303 315 420
AJ-02YSTF(L)2YDB2Y   3x4x1,4 / 12x4x0,9 STI  A  ARCOR TNP 02 5214200 724 44 2140 347 330 440
AJ-02YSTF(L)2YDB2Y   3x4x1,4 / 30x4x0,9 STI  A  ARCOR TNP 02 5230200 1182 56 3300 499 420 560
AJ-02YSTF(L)2YDB2Y   4x4x1,4 / 13x4x0,9 STI  A  ARCOR TNP 02 5217700 823 46 2330 385 345 460
AJ-02YSTF(L)2YDB2Y   5x4x1,4 / 16x4x0,9 STI  A  ARCOR TNP 02 5221200 974 48 2580 445 360 480
AJ-02YSTF(L)2YDB2Y    10x4x0,9 STI  B  ARCOR TNP 02 5208300 576 38 1730 210 285 380
AJ-02YSTF(L)2YDB2Y    16x4x0,9 STI  B  ARCOR TNP 02 5218300 785 42 2290 351 315 420
AJ-02YSTF(L)2YDB2Y    19x4x0,9 STI  B  ARCOR TNP 02 5219300 861 43 2450 379 320 430
AJ-02YSTF(L)2YDB2Y    24x4x0,9 STI  B  ARCOR TNP 02 5223300 1068 50 2970 437 375 500
AJ-02YSTF(L)2YDB2Y    30x4x0,9 STI  B  ARCOR TNP 02 5227300 1243 52 3290 496 390 520
AJ-02YSTF(L)2YDB2Y   1x4x1,4 /  7x4x0,9 STI  B  ARCOR TNP 02 5206300 561 35 1650 293 260 350
AJ-02YSTF(L)2YDB2Y   2x4x1,4 / 11x4x0,9 STI  B  ARCOR TNP 02 5209300 815 43 2230 396 320 430
AJ-02YSTF(L)2YDB2Y   3x4x1,4 / 12x4x0,9 STI  B  ARCOR TNP 02 5214300 902 44 2330 433 330 440
AJ-02YSTF(L)2YDB2Y   3x4x1,4 / 30x4x0,9 STI  B  ARCOR TNP 02 5230300 1507 57 3640 636 425 570
AJ-02YSTF(L)2YDB2Y   4x4x1,4 / 13x4x0,9 STI  B  ARCOR TNP 02 5217800 989 47 2510 463 350 470
AJ-02YSTF(L)2YDB2Y   5x4x1,4 / 16x4x0,9 STI  B  ARCOR TNP 02 5221300 1194 49 2810 547 365 490
AJ-02YSTF(L)2YDB2Y    10x4x0,9 STI  C  ARCOR TNP 02 5208400 1022 40 2820 465 300 400
AJ-02YSTF(L)2YDB2Y    16x4x0,9 STI  C  ARCOR TNP 02 5218400 1226 44 3290 534 330 440
AJ-02YSTF(L)2YDB2Y    19x4x0,9 STI  C  ARCOR TNP 02 5219400 1302 46 3470 558 345 460
AJ-02YSTF(L)2YDB2Y    24x4x0,9 STI  C  ARCOR TNP 02 5223400 1531 52 4110 610 390 520
AJ-02YSTF(L)2YDB2Y    30x4x0,9 STI  C  ARCOR TNP 02 5227400 1735 55 4480 672 410 550
AJ-02YSTF(L)2YDB2Y   1x4x1,4 /  7x4x0,9 STI  C  ARCOR TNP 02 5206400 783 37 2300 411 275 370
AJ-02YSTF(L)2YDB2Y   2x4x1,4 / 11x4x0,9 STI  C  ARCOR TNP 02 5209400 1324 45 3310 645 335 450
AJ-02YSTF(L)2YDB2Y   3x4x1,4 / 12x4x0,9 STI  C  ARCOR TNP 02 5214400 1411 47 3430 680 350 470
AJ-02YSTF(L)2YDB2Y   3x4x1,4 / 30x4x0,9 STI  C  ARCOR TNP 02 5230400 2021 59 4900 855 440 590
AJ-02YSTF(L)2YDB2Y   4x4x1,4 / 13x4x0,9 STI  C  ARCOR TNP 02 5217900 1498 49 3640 703 365 490
AJ-02YSTF(L)2YDB2Y   5x4x1,4 / 16x4x0,9 STI  C  ARCOR TNP 02 5221400 1686 52 3960 773 390 520
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.