Print Icon

BayRail® PZB control cables, rail foot, permanent laying, connection cable

A-2YTF(L)...
A-02YSTF(L)...

PZB Cable acc. to DB Dlk 1.013.168y, TL 416.0119, TL 416.0121


NT40_2YTF2Y(L)2Y_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!36-Längswasserdicht38-Querwasserdicht40-Geschirmt50-Verlegung -5

 


Standards

Dlk 1.013.168y, TL 416.0119, TL 416.0121,
Bayka BayRail company standard.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor cross-section mm²
A-2YTF2Y(L)2Y 1x4x0.75 mm²
A-2YTF(L)2YV 1x4x0.75 mm²
0.75  
Conductor diameter mm
A-02YSTF(L)2YB2Y/...(SR)2Y 1x4x0.8
  0.8
Conductor resistance of the pair of cores Ω/km ≤ 51.4 ≤ 73.2
Resistance difference Ω/km ≤ 0.9 ≤ 0.69
Insulation resistance GΩxkm ≥ 5 ≥ 5
Mutual capacitance at 800 Hz nF/km ≤ 38 ≤ 30
50 Hz alternating voltage test    
Core-core Veff   2500
Core-screen Veff   2500
Temperature ranges    
When laying, installing °C   -5 to +50
Before and after laying, installing °C   -30 to +70
(PZB control cable to +80)    

Application

PZB control cables according to Dlk 1.013.168y are used for controlling the track and switching magnets of the PZB. The cables are permitted for laying along the rail foot for train speeds ≤ 160 km/h.

PZB control cables according to TL 416.0119 are used for controlling the track and switching magnets of the PZB. Cables with solid conductors can be laid in the ground, in trough channels, in pipe conduits, and on cable holders in shaft and tunnel walls.

PZB connection cables according to TL 416.0121 are used for directly connecting the track and switching magnets, and/or the relay and switching units of the intermittent train running control (PZB track-side equipment).

The PZB cables must be used according to the effective maintenance guidelines.

Type Designation Codes

A outdoor cable
2Y  insulating cover made of polyethylene (PE)
02YS conductor insulation made of foam skin
TF C=cable dry filled with swelling yarns and swelling fleeces
(L)2Y laminated sheath made of polyethylene
(L)2YV laminated sheath made from polyethylene, reinforced
B armouring made of band steel
(SR) armouring made of steel channel binding
2Y outer sheath made of PE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

PZB-Steuerkabel A-02YSTF(L)2Y(SR)2Y 1x4x0,8


Print Icon

BayRail® PZB control cables, rail foot, permanent laying, connection cable

A-2YTF(L)...
A-02YSTF(L)...

PZB Cable acc. to DB Dlk 1.013.168y, TL 416.0119, TL 416.0121

Product Bayka Order No. Customer Order-No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YTF(L)2YV   1x4x0,75 RF     Dlk 1.013.168y      (00698455) 5700000 00698455 32 17 185 15 85 170
A-2YTF2Y(L)2Y  1x4x0,75 RF     DB 416.0121  (807348) 5700200 00807348 33 18 270 15 90 180
A-02YSTF(L)2YB2Y       1x4x0,8 STI   DB 416.0119   (00722531) 5700100 00722531 23 16 170 0 0 0
A-02YSTF(L)2Y(SR)2Y    1x4x0,8 STI   DB 416.0119   (00731162) 5700400 00731162 23 18 290 11 90 180
Tensile stress only valid when cable sheath and cable core involved.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.