BayRail® Signalling cables, quad stranded, (H45)
AJ-2Y(L)2YDB2Y
...x4x1,4 acc. to DB TL 416.0115














Standards
Technical specifications 416.0115,
Engineering specifications 416.0116,
Bayka BayRail company standard.
The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2011/65/EU - RoHS 2.0 and Regulation No. 1907/2006 (REACH).
Technical Data
Conductor diameter mm | 1.4 |
Conductor resistance (pair of cores) Ω/km | ≤ 23.4 |
Insulation resistance GΩxkm | ≥ 10 |
Mutual capacitance at 800 Hz nF/km | ≤ 45 |
For the central quad nF/km | ≤ 50 |
Alternating voltage test 50 Hz | |
Core-core Veff | 2500 |
Core-screen Veff | 2500 |
Temperature ranges | |
During laying, installing °C | -10 to +60 |
Before and after laying, installing °C | -40 to +60 |
Application
As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.
Type Designation Codes
AJ | outdoor cable with inductive protection |
2Y | insulating cover made of polyethylene (PE) |
(L)2Y | laminated sheath made of polyethylene |
D | screen made of copper wires |
B | armouring |
2Y | outer sheath made of PE |
S | signalling cable |
(H45) | maximum mutual capacitance value at 800 Hz, 45 nF/km |
rk | reduction factor characteristic |
Order Example
AJ-2Y(L)2YDB2Y 7x4x1,4 S (H45)
BayRail® Signalling cables, quad stranded, (H45)
AJ-2Y(L)2YDB2Y
...x4x1,4 acc. to DB TL 416.0115
Tensile stress only valid when cable sheath and cable core involved.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
*) N/A (not applicable) Cable is not subject to the Construction Products Regulation CPR
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
*) N/A (not applicable) Cable is not subject to the Construction Products Regulation CPR