Download IconPrint Icon

BayRail® Signalling cables, core-stranded, PVC sheath

A-2YY

...x1x1,4 acc. to DB Dlk 1.013.102y


NT33_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!50-Verlegung -5

 


Standards

Dlk 1.013.102y and/or DIN VDE 0816-part 2.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance Ω/km ≤ 11.9
Insulation resistance GΩxkm ≥ 5
Mutual capacitance at 800 Hz nF/km ≤ 120
For the central cores and the cores in the outer layer ≤ 130
Alternating voltage test 50 Hz  
Core-core Veff 2500
Core-screen Veff 2500
Temperature range  
During laying, installing °C -5 to +60
Before and after laying, installing °C -30 to +70

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

Type Designation Codes

A outdoor cable
2Y core insulation made of PE
Y outer sheath made of PVC
S signalling cable
(H120) maximum mutual capacitance value at 800 Hz, 120 nF/km

Additional Informations

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

A-2YY 40x1x1,4 S (H120)


Print Icon

BayRail® Signalling cables, core-stranded, PVC sheath

A-2YY

...x1x1,4 acc. to DB Dlk 1.013.102y

Product CPR DoP *) Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YY         2x1x1,4 S (H120) N/A 5707800 31 11 130 15 55 110
A-2YY         4x1x1,4 S (H120) N/A 5707810 62 11 160 28 55 110
A-2YY         5x1x1,4 S (H120) N/A 5710200 77 12 180 35 60 120
A-2YY         8x1x1,4 S (H120) N/A 5710600 123 13 230 55 65 130
A-2YY        12x1x1,4 S (H120) N/A 5711000 185 15 350 80 75 150
A-2YY        16x1x1,4 S (H120) N/A 5710300 246 17 420 110 85 170
A-2YY        21x1x1,4 S (H120) N/A 5710800 323 18 530 150 90 180
A-2YY        27x1x1,4 S (H120) N/A 5710400 416 20 650 180 85 170
A-2YY        33x1x1,4 S (H120) N/A 5711400 508 22 770 220 110 220
A-2YY        40x1x1,4 S (H120) N/A 5711200 616 23 900 260 115 230
A-2YY        48x1x1,4 S (H120) N/A 5711410 739 26 1100 320 120 260
A-2YY        56x1x1,4 S (H120) N/A 5712600 862 27 1250 370 135 270
A-2YY        65x1x1,4 S (H120) N/A 5712700 1001 29 1410 430 145 290
A-2YY        75x1x1,4 S (H120) N/A 5711420 1154 31 1600 480 155 310
A-2YY        80x1x1,4 S (H120) N/A 5707400 1232 32 1700 510 160 320
A-2YY        96x1x1,4 S (H120) N/A 5714900 1478 34 2000 600 170 340
A-2YY       114x1x1,4 S (H120) N/A 5715200 1755 37 2380 700 185 370
A-2YY       133x1x1,4 S (H120) N/A 5711430 2047 39 2730 790 195 390
A-2YY       154x1x1,4 S (H120) N/A 5715400 2371 42 3150 890 210 420
A-2YY       176x1x1,4 S (H120) N/A 5711440 2709 45 3650 990 225 450
A-2YY       200x1x1,4 S (H120) N/A 5716000 3079 48 4100 1000 240 480
The cable is for installation in the ground or outside structures and is therefore not subject to the CPR. It cannot be classified as Eca or better.