Download IconPrint Icon

BayRail® Signalling cables, core-stranded, PVC sheath

A-2YY

...x1x1,8 acc. to DB Dlk 1.013.102y


NT33_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!50-Verlegung -5

 


Standards

Dlk 1.013.102y and/or DIN VDE 0816-part 2.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.8
Conductor resistance Ω/km ≤ 7.2
Insulation resistance GΩxkm ≥ 5
Mutual capacitance at 800 Hz nF/km ≤ 130
For the central cores and the cores in the outer layer ≤ 140
Alternating voltage test 50 Hz  
Core-core Veff 2500
Core-screen Veff 2500
Temperature range  
During laying, installing °C -5 to +50
Before and after laying, installing °C -30 to +70

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

Type Designation Codes

A outdoor cable
2Y core insulation made of PE
Y outer sheath made of PVC
S signalling cable
(H130) maximum mutual capacitance value at 800 Hz, 130 nF/km

Additional Informations

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

A-2YY 40x1x1,8 S (H130)


Print Icon

BayRail® Signalling cables, core-stranded, PVC sheath

A-2YY

...x1x1,8 acc. to DB Dlk 1.013.102y

Product CPR DoP *) Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YY         4x1x1,8 S (H130) N/A 5712200 102 12 205 44 80 150
A-2YY         5x1x1,8 S (H130) N/A 5712210 127 13 245 55 80 160
A-2YY         8x1x1,8 S (H130) N/A 5712220 204 15 345 90 90 180
A-2YY        12x1x1,8 S (H130) N/A 5712230 305 17 475 135 110 210
A-2YY        16x1x1,8 S (H130) N/A 5712240 407 19 605 180 120 230
A-2YY        21x1x1,8 S (H130) N/A 5712250 534 21 765 230 130 260
A-2YY        27x1x1,8 S (H130) N/A 5712260 687 24 950 300 150 290
A-2YY        33x1x1,8 S (H130) N/A 5712270 840 26 1155 360 160 320
A-2YY        40x1x1,8 S (H130) N/A 5712280 1018 28 1370 430 170 340
A-2YY        48x1x1,8 S (H130) N/A 5712290 1221 31 1620 500 190 370
A-2YY        56x1x1,8 S (H130) N/A 5778100 1425 32 1860 570 200 360
A-2YY        65x1x1,8 S (H130) N/A 5778110 1654 34 2125 650 210 420
A-2YY        75x1x1,8 S (H130) N/A 5778120 1908 38 2465 740 230 460
A-2YY        80x1x1,8 S (H130) N/A 5778130 2036 38 2615 780 240 470
A-2YY        96x1x1,8 S (H130) N/A 5778140 2443 41 3095 910 250 500
A-2YY       114x1x1,8 S (H130) N/A 5778150 2901 45 3625 1050 270 540
A-2YY       133x1x1,8 S (H130) N/A 5778160 3384 49 4285 1190 300 590
A-2YY       154x1x1,8 S (H130) N/A 5778170 3919 52 4910 1340 320 630
A-2YY       176x1x1,8 S (H130) N/A 5778180 4479 55 5560 1510 330 660
A-2YY       200x1x1,8 S (H130) N/A 5778190 5089 59 6385 1690 360 720
The cable is for installation in the ground or outside structures and is therefore not subject to the CPR. It cannot be classified as Eca or better.