Download IconPrint Icon

BayRail® Signalling cables, core-stranded, armoured, PVC sheath

A-2YYbY

...x1x1,4 acc. to DB Dlk 1.013.102y


NT34_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!44-Nagetierschutz46-Robust50-Verlegung -5

 


Standards

Dlk 1.013.102y and/or DIN VDE 0816-part 2.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance Ω/km ≤ 11.9
Insulation resistance GΩxkm ≥ 5
Mutual capacitance at 800 Hz nF/km ≤ 120
For the central cores and the cores in the outer layer ≤ 130
Alternating voltage test 50 Hz  
Core-core Veff 2500
Core-screen Veff 2500
Temperature range  
During laying, installing °C -5 to +50
Before and after laying, installing °C -30 to +70

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

Type Designation Codes

A outdoor cable
2Y core insulation made of PE
Y inner sheath made of PVC
b armouring, one layer steel tape 0.3 mm (1B 0.3)
Y outer sheath made of PVC
S signalling cable
(H120) maximum mutual capacitance value
at 800 Hz, 120 nF/km

Additional Informations

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

A-2YYbY 40x1x1,4 S (H120) (1B 0,3)


Print Icon

BayRail® Signalling cables, core-stranded, armoured, PVC sheath

A-2YYbY

...x1x1,4 acc. to DB Dlk 1.013.102y

Product CPR DoP *) Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YYbY       2x1x1,4 S (H120)  (1B 0,3) N/A 5765000 31 15.5 325 15 130 190
A-2YYbY       4x1x1,4 S (H120)  (1B 0,3) N/A 5765200 62 16 340 30 100 200
A-2YYbY       5x1x1,4 S (H120)  (1B 0,3) N/A 5765300 77 17 380 40 100 200
A-2YYbY       8x1x1,4 S (H120)  (1B 0,3) N/A 5765400 123 18 470 60 110 220
A-2YYbY      12x1x1,4 S (H120)  (1B 0,3) N/A 5765100 185 20 590 90 125 250
A-2YYbY      16x1x1,4 S (H120)  (1B 0,3) N/A 5765500 246 22.5 785 120 135 270
A-2YYbY      21x1x1,4 S (H120)  (1B 0,3) N/A 5740100 323 24.5 850 150 125 250
A-2YYbY      27x1x1,4 S (H120)  (1B 0,3) N/A 5765600 416 26.5 1000 190 160 320
A-2YYbY      33x1x1,4 S (H120)  (1B 0,3) N/A 5765700 508 28 1150 230 170 340
A-2YYbY      40x1x1,4 S (H120)  (1B 0,3) N/A 5766500 616 29 1310 270 175 350
A-2YYbY      48x1x1,4 S (H120)  (1B 0,3) N/A 5764900 739 32 1550 320 190 380
A-2YYbY      56x1x1,4 S (H120)  (1B 0,3) N/A 5765800 862 33 1710 370 200 400
A-2YYbY      65x1x1,4 S (H120)  (1B 0,3) N/A 5767000 1001 35 1980 430 210 420
A-2YYbY      80x1x1,4 S (H120)  (1B 0,3) N/A 5767400 1232 38 2300 510 230 460
A-2YYbY      96x1x1,4 S (H120)  (1B 0,3) N/A 5767500 1478 41 2650 600 245 490
A-2YYbY     114x1x1,4 S (H120)  (1B 0,3) N/A 5767800 1755 45 3200 700 270 540
A-2YYbY     133x1x1,4 S (H120)  (1B 0,3) N/A 5768000 2047 47 3600 790 285 570
A-2YYbY     176x1x1,4 S (H120)  (1B 0,3) N/A 5768200 2710 53 4600 990 320 640
A-2YYbY     200x1x1,4 S (H120)  (1B 0,3) N/A 5768300 3079 56 5100 1100 340 680
The cable is for installation in the ground or outside structures and is therefore not subject to the CPR. It cannot be classified as Eca or better.