Download IconPrint Icon

BayRail® Signalling cables, core-stranded, armoured, PVC sheath

A-2YYbY

...x1x1,8 acc. to DB Dlk 1.013.102y


NT34_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!44-Nagetierschutz46-Robust50-Verlegung -5

 


Standards

Dlk 1.013.102y and/or DIN VDE 0816-part 2.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.8
Conductor resistance Ω/km ≤ 7.2
Insulation resistance GΩxkm ≥ 5
Mutual capacitance at 800 Hz nF/km ≤ 130
For the central cores and the cores in the outer layer ≤ 140
Alternating voltage test 50 Hz  
Core-core Veff 2500
Core-screen Veff 2500
Temperature range  
During laying, installing °C -5 to +50
Before and after laying, installing °C -30 to +70

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

Type Designation Codes

A outdoor cable
2Y core insulation made of PE
Y inner sheath made of PVC
b armouring, one layer steel tape 0.3 mm (1B 0.3)
Y outer sheath made of PVC
S signalling cable
(H130) maximum mutual capacitance value
at 800 Hz, 130 nF/km

Additional Informations

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

A-2YYbY 40x1x1,8 S (H130) (1B 0,3)


Print Icon

BayRail® Signalling cables, core-stranded, armoured, PVC sheath

A-2YYbY

...x1x1,8 acc. to DB Dlk 1.013.102y

Product CPR DoP *) Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YYbY       4x1x1,8 S (H130)  (1B 0,3) N/A 5766000 102 17 425 50 140 205
A-2YYbY       8x1x1,8 S (H130)  (1B 0,3) N/A 5766300 204 20.5 675 100 160 240
A-2YYbY      12x1x1,8 S (H130)  (1B 0,3) N/A 5766400 306 24 925 145 190 290
A-2YYbY      16x1x1,8 S (H130)  (1B 0,3) N/A 5766600 407 25 990 200 200 300
A-2YYbY      27x1x1,8 S (H130)  (1B 0,3) N/A 5766800 687 31 1605 310 250 370
A-2YYbY      40x1x1,8 S (H130)  (1B 0,3) N/A 5766700 1018 35 1980 450 280 420
A-2YYbY      56x1x1,8 S (H130)  (1B 0,3) N/A 5769000 1425 40 2820 580 320 480
The cable is for installation in the ground or outside structures and is therefore not subject to the CPR. It cannot be classified as Eca or better.