Download IconPrint Icon

BayRail® Signalling cables, quad stranded, screened, armoured, PVC sheath

A-2Y(St)YbY

...x4x0,9 acc. to DB Dlk 1.013.201y


NT35_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!38-Querwasserdicht40-Geschirmt44-Nagetierschutz46-Robust50-Verlegung -5

 


Standards

Dlk 1.013.201y and/or DIN VDE 0816-part 2.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.9
Conductor resistance (pair of cores) Ω/km ≤ 28.9
Insulation resistance GΩxkm ≥ 5
Mutual capacitance at 800 Hz nF/km ≤ 100
Capacitive couplings pF for 300 m at 800 Hz
K1 ≤ 400
K9-12 ≤ 300
Alternating voltage test 50 Hz  
Core-core Veff 2500
Core-screen Veff 2500
Temperature range  
During laying, installing °C -5 to +50
Before and after laying, installing °C -30 to +70

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

Type Designation Codes

A outdoor cable
2Y core insulation made of PE
(St) static screen
Y inner sheath made of PVC
b armouring
Y outer sheath made of PVC
S signalling cable
(H45) maximum mutual capacitance value at 800 Hz, 45 nF/km

Additional Informations

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

A-2Y(St)YbY 10x4x0,9 S (H45) (1B 0,3)


Print Icon

BayRail® Signalling cables, quad stranded, screened, armoured, PVC sheath

A-2Y(St)YbY

...x4x0,9 acc. to DB Dlk 1.013.201y

Product CPR DoP *) Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2Y(St)YbY       1x4x0,9 S Lg   (1B 0.3)          (00128961) N/A 5736000 58 16 365 12 128 192
A-2Y(St)YbY       3x4x0,9 S Lg   (1B 0.3)          (00128962) N/A 5736200 128 21 535 0 0 0
A-2Y(St)YbY       5x4x0,9 S Lg   (1B 0.3)          (00128963) N/A 5736300 188 24 730 0 0 0
A-2Y(St)YbY       7x4x0,9 S Lg   (1B 0.3)          (00128964) N/A 5736400 243 25 820 0 0 0
A-2Y(St)YbY      10x4x0,9 S Lg   (1B 0.3)          (00128965) N/A 5736700 355 30 1070 0 0 0
A-2Y(St)YbY      14x4x0,9 S Lg   (1B 0.3)          (00128966) N/A 5736800 468 33.5 1450 165 272 408
A-2Y(St)YbY      20x4x0,9 S Lg   (1B 0.3)          (00128967) N/A 5737000 633 27 1840 235 296 444
A-2Y(St)YbY      30x4x0,9 S Lg   (1B 0.3)          (00128968) N/A 5738000 911 43 2430 340 360 540
The cable is for installation in the ground or outside structures and is therefore not subject to the CPR. It cannot be classified as Eca or better.