BayEnergy® Power cables, PVC insulation, PVC sheath

NYY-O

3-cores acc. to DIN VDE 0276


AT104_NYY-O_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung16-Inhouse10-Verlegung im Freien, UV-Schutz beachten!30-Ölbeständig_bedingt50-Verlegung -5

optional

Verlegung -25 -30 -40 optionalUV-beständig optionalÖlbeständig optional

Standards

DIN VDE 0276-603 part 3G / HD 603.1 and IEC 60502-1.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are flame retardant and self-extinguishing according to DIN EN 50265-2-1 (IEC 60332-1-2) and free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

Technical Data

Rated voltage kV 0.6/1
Testing voltage kV 4
Cable temperature ºC
during laying (min)
after laying (max)


-5
+70

Max. permissible operating temperature (conductor) °C +70
Short-circuit temperature °C +160
Current carrying capacity
acc. to HD 603 S1-1994 3G
during regular operation: table 14+15
in case of short-circuit: table 17 short-circuit duration max 5s
 

Application

For indoor and outdoor installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where mechanical damage to the cable is not expected (see DIN VDE 0298-1).

The cables are insensitive to occasional impacts of oils and fuels.

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
Y insulation made of polyvinyl chloride (PVC)
Y outer sheath made of polyvinyl chloride (PVC)
O cable without green-yellow core
RE circular conductor, solid
RM circular conductor, stranded
SM sector-shaped conductor, stranded

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

NYY-O 3x150 SM 0,6/1 kV


Print Icon

BayEnergy® Power cables, PVC insulation, PVC sheath

NYY-O

3-cores acc. to DIN VDE 0276

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
NYY-O       3x1,5 RE   0,6/1kV 4042104 43 13 235 0.17 23 80 160
NYY-O       3x2,5 RE   0,6/1kV 4042804 72 13 275 0.29 38 80 160
NYY-O         3x4 RE   0,6/1kV 4042904 115 16 390 0.46 60 95 190
NYY-O         3x6 RE   0,6/1kV 4042404 173 17 480 0.69 90 100 200
NYY-O        3x10 RE   0,6/1kV 4042504 288 18 640 1.15 150 115 230
NYY-O        3x16 RE   0,6/1kV 4043204 461 20 855 1.84 240 125 250
NYY-O        3x25 RM   0,6/1kV 4042704 720 26 1350 0.00 0 0 0
NYY-O        3x35 SM   0,6/1kV 4043004 1008 25 1530 0.00 0 0 0
NYY-O        3x50 SM   0,6/1kV 4043104 1440 28 1955 5.75 750 170 340
NYY-O        3x70 SM   0,6/1kV 4043404 2016 32 2690 8.05 1050 190 380
NYY-O        3x95 SM   0,6/1kV 4043304 2736 36 3615 0.00 0 0 0
NYY-O       3x120 SM   0,6/1kV 4043504 3456 38 4345 13.80 1800 235 470
NYY-O       3x150 SM   0,6/1kV 4043704 4320 43 5345 17.25 0 0 0
NYY-O       3x185 SM   0,6/1kV 4043604 5328 47 6600 0.00 0 0 0
NYY-O       3x240 SM   0,6/1kV 4043804 6912 53 8525 27.60 3600 320 640
NYY-O       3x300 SM   0,6/1kV 4043904 8819 59 10550 34.50 4500 355 710
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.