BayEnergy® Power cables, PVC insulation, concentric conductor, PVC sheath

NYCY

multicore acc. to DIN VDE 0276


AT131_NYCY_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung16-Inhouse10-Verlegung im Freien, UV-Schutz beachten!30-Ölbeständig_bedingt50-Verlegung -5

 


Standards

DIN VDE 0276-627 part 4H / HD 627 S1 and IEC 60502-1,
cores with black numbering printed.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

They are flame retardant and self-extinguishing according to DIN EN 60332-1-2 (IEC 60332-1-2) and free of silicone, cadmium and free from substances harmful to the wetting properties of lacquers.

Technical Data

Rated voltage kV 0.6/1
Testing voltage kV 4
Cable temperature ºC
during laying (min)
after laying (max)


-5
+70

Max. permissible operating temperature (conductor) °C +70
Short-circuit temperature °C +160
Current carrying capacity
acc. to HD 603 S1:1996 4H
 

Application

For indoor and outdoor installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where protection against contact voltage is required in the case of mechanical damage. (See DIN VDE 0298-1.)

The cables are insensitive to occasional impacts of oils and fuels.

Type Designation Codes

N cables acc. to standard
(N) cables based on standard
Y insulation made of polyvinyl chloride (PVC)
C Concentric Cu-conductor
Y outer sheath made of polyvinyl chloride (PVC)
J cable with green-yellow core
O cable without green-yellow core
RE circular conductor, solid
RM circular conductor, stranded
SM sector-shaped conductor, stranded

Order Example

NYCY 8 x 2,5 RE/4 0,6/1 kV


Print Icon

BayEnergy® Power cables, PVC insulation, concentric conductor, PVC sheath

NYCY

multicore acc. to DIN VDE 0276

Product CPR DoP *) Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
NYCY     7x1,5 RE/2,5  0,6/1kV Eca 4153400 133 17 420 0.17 53 100 200
NYCY     7x2,5 RE/2,5  0,6/1kV Eca 4146800 200 18 510 0.29 88 110 220
NYCY       7x4 RE/4    0,6/1kV Eca 4147800 315 21 720 0.46 140 130 260
(N)YCY     7x6 RE/6    0,6/1kV Eca 4148000 470 22 920 0.69 210 140 280
NYCY     8x1,5 RE/2,5  0,6/1kV Eca 4122600 147 18 470 0.17 60 115 220
NYCY     8x2,5 RE/4    0,6/1kV Eca 4154000 238 19 590 0.29 100 120 240
NYCY       8x4 RE/6    0,6/1kV Eca 4148210 374 22 830 0.46 160 130 260
(N)YCY     8x6 RE/6    0,6/1kV Eca 4148200 535 23 1030 0.69 240 140 280
(N)YCY    8x10 RE/10   0,6/1kV Eca 4181000 902 26 1450 1.15 400 160 320
NYCY    10x1,5 RE/2,5  0,6/1kV Eca 4152100 176 20 550 0.17 75 120 240
NYCY    10x2,5 RE/4    0,6/1kV Eca 4155000 286 21 700 0.29 125 130 260
NYCY      10x4 RE/6    0,6/1kV Eca 4152200 443 25 1000 0.46 200 150 300
NYCY    12x1,5 RE/2,5  0,6/1kV Eca 4146100 205 20 610 0.17 90 120 240
NYCY    12x2,5 RE/4    0,6/1kV Eca 4147100 334 22 770 0.29 150 130 260
NYCY      12x4 RE/6    0,6/1kV Eca 4136800 528 26 1100 0.46 240 160 320
(N)YCY    12x6 RE/10   0,6/1kV Eca 4181100 829 28 1430 0.69 360 170 340
(N)YCY   12x10 RE/10   0,6/1kV Eca 4180300 1300 31 2010 1.15 600 190 380
NYCY    14x1,5 RE/2,5  0,6/1kV Eca 4146200 234 21 660 0.17 105 130 260
NYCY    14x2,5 RE/6    0,6/1kV Eca 4147200 403 23 870 0.29 175 140 280
NYCY      14x4 RE/6    0,6/1kV Eca 4136900 619 27 1230 0.46 280 160 320
(N)YCY    14x6 RE/10   0,6/1kV Eca 4180200 965 29 1600 0.69 420 180 360
NYCY    16x1,5 RE/4    0,6/1kV Eca 4145100 276 22 740 0.17 120 130 260
NYCY    16x2,5 RE/6    0,6/1kV Eca 4155100 451 24 960 0.29 200 150 300
NYCY    19x1,5 RE/4    0,6/1kV Eca 4145300 320 23 805 0.17 143 140 280
NYCY    19x2,5 RE/6    0,6/1kV Eca 4147400 523 25 1060 0.29 238 150 300
NYCY      19x4 RE/10   0,6/1kV Eca 4137000 826 29 1560 0.46 380 180 360
NYCY    21x1,5 RE/6    0,6/1kV Eca 4146300 369 24 900 0.17 158 150 300
NYCY    21x2,5 RE/10   0,6/1kV Eca 4148300 571 26 1190 0.29 263 160 320
(N)YCY    21x4 RE/10   0,6/1kV Eca 4180000 926 31 1720 0.46 420 190 380
NYCY    24x1,5 RE/6    0,6/1kV Eca 4146400 413 26 1010 0.17 180 160 320
NYCY    24x2,5 RE/10   0,6/1kV Eca 4147500 696 28 1330 0.29 300 170 340
(N)YCY    24x4 RE/10   0,6/1kV Eca 4180100 1035 34 1990 0.46 480 210 420
(N)YCY    24x6 RE/10   0,6/1kV Eca 4180400 1559 38 2570 0.69 720 230 460
NYCY    27x1,5 RE/6    0,6/1kV Eca 4146410 457 26 1080 0.17 203 160 320
NYCY    27x2,5 RE/10   0,6/1kV Eca 4147510 736 29 1430 0.29 338 180 360
NYCY    30x1,5 RE/6    0,6/1kV Eca 4146500 499 27 1180 0.17 225 160 320
NYCY    30x2,5 RE/10   0,6/1kV Eca 4148100 840 30 1540 0.29 375 180 360
NYCY    37x1,5 RE/10   0,6/1kV Eca 4136700 642 29 1390 0.17 278 180 360
NYCY    37x2,5 RE/10   0,6/1kV Eca 4147710 971 32 1810 0.29 463 190 380
NYCY    40x1,5 RE/10   0,6/1kV Eca 4147600 696 30 1470 0.17 300 180 360
NYCY    40x2,5 RE/10   0,6/1kV Eca 4148700 1080 33 1940 0.29 500 200 400
NYCY    52x1,5 RE/10   0,6/1kV Eca 4191000 865 34 1810 0.17 390 200 400
NYCY    52x2,5 RE/10   0,6/1kV Eca 4191300 1342 38 2470 0.29 650 230 460
NYCY    61x1,5 RE/10   0,6/1kV Eca 4119200 998 36 2100 0.17 458 220 440
NYCY    61x2,5 RE/10   0,6/1kV Eca 4191400 1584 39 2790 0.29 763 240 480
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.
*) CPR Construction Products Regulation Class,
DoP Declaration of Performance.
The DoP applies exclusively to Bayka cables.