BayEnergy® Power cables, Al, flexible


1-core based on HD 603 S1



10-Verlegung im Freien, UV-Schutz beachten!04-Rohrverlegung08-Trogverlegung22-UV-bedingt16-Inhouse24-Flammwidrig


Flammwidrig optionalRaucharm optional


based on HD 603 S1,
flame retardant acc. to VDE 0482-332-1-2 (EN 60332-1-2),
ozone test acc. to ISO 1431-1 (appr. 1000h without cracks).

based on HD 603 S1,
Toxizität nach DIN EN 50305 (VDE 0260 Teil ,305):2003-03, Abschnitt 9.2,
low toxicity of gases acc. to DIN EN 61034-2 (VDE 0482-1034-2):2006-03,
flame retardant acc. to DIN VDE 0472 part 804:1989-11, category „C“,
ozone test acc. to ISO 1431-1 (appr. 1000h without cracks).

Technical Data

Circular  aluminium conductor, conduktor class 2, insulation made of crosslinked polyolefin compound, outer sheath made of special compound containing halogens.

Rated voltage kV 0,6/1
Testing voltage kV 10

Cable temperature ºC
during laying (min)
after laying (max)

Max. permissible operating temperature (conductor) °C +90
Short-circuit temperature °C +250
Current carrying capacity
acc. HD 603 S1-1994 3G23
during regular operation
in case of short-circuit

table 14+15
table 17
short-circuit duration max 5


Cable with improved flexibility, espezially for use in wind für den Einsatz in wind energy towers, for indoor and outdoor installation, in open air (protected against direct sun light), however not directly in the ground, for power stations, industry and distribution boards or subscriber networks.

NA2XY-O is for installation directly in the ground.

Type Designation Codes

N cables acc. to standard
A conductor made of aluminium
2X core insulation made of cross-linked polyethylene (XLPE)
Y core insulation made of special compound
H sheath made of thermoplastic, halogen-free polyolefin
O cable without green-yellow core
RMu circular conductor, stranded, not compacted

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

NA2XY-O 1x240 RMu 0,6/1kV
NA2XH-O 1x240 RMu 0,6/1kV

Print Icon

BayEnergy® Power cables, Al, flexible


1-core based on HD 603 S1

Product Bayka Order No. Al-No. Outer ∅
Net weight
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km kA daN min. mm min. mm  
NA2XY-O    1x185 RMu  0,6/1 kV 4400120 536 26 825 17.39 555 205 410
NA2XY-O    1x240 RMu  0,6/1 kV 4400100 696 28 1020 22.57 720 220 440
NA2XY-O    1x300 RMu  0,6/1 kV 4400125 870 31 1245 28.21 900 235 465
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.