Download IconPrint Icon

BayEnergy® Theft defending railway grounding cables

(N)2X CuStAl

1-core acc. to Bayka standard BayEnergy 01, resp. 02


CT31_(N)2X_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!16-Inhouse42-Flexibel23-Halogenfrei20-UV-beständig51-Verlegung -10

 


Standards

Bayka company standard BayEnergy 01.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Rated voltage U0/U kV 0.6/1
Nominal cross-section mm² 70
Conductor resistance Ω/km ≤ 0.375

Short-circuit current
according to Deutsche Bahn standard 997.0205A01 (1.3.2003) paragraph 2 "current carrying capability"

 

Permissible temperature range ºC
during laying, installing and similar
before and after laying


-10 to +60
-30 to +60

Application

BayEnergy® flexible railway grounding cables are used as grounding connection resistant to short-circuit current, for potential equalisation between rails and other conductive parts not under voltage. They are especially used, where high flexibility and a low bending radius are required. The grounding cable is halogen-free, suitable for indoor and outdoor applications and for direct burying. The advanced and improved railway grounding cables are marked using two blue Bayka identification strips® on the outer sheath, and document Bayka quality "made in Germany".

BayEnergy® flexible railway grounding cables are approved by Germany's Federal Railway Office (EBA) and released for use in the area of operation of Deutsche Bahn AG.

The imprint "Eigentum DB" (Property of DB) or "Eigentum Verkehrsbetriebe" (Property of the Transport Services) is used as property notice and as theft protection. BayEnergy® aluminium railway grounding cables can be easily differentiated from copper grounding cables keeping potential thieves away.

Further properties:

  • Resistant against impact, vibration and shock loads
  • UV-resistant
  • Torsion-free laying can be easily checked
  • Easy laying and installation, handling with standard tools

Type Designation Codes

(N) cables based on standard
2X sheath made of cross-linked polyethylene (XLPE)
H outer protective sheath made from halogen-free, flame-retardant copolymer
1x70 no. of cores x cross-section
RF circular conductor, finely stranded
CuStAl conductor made from copper wires  and copper-plated aluminium and steel wires

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

(N)2X 1x70 RF CuStAl


Print Icon

BayEnergy® Theft defending railway grounding cables

(N)2X CuStAl

1-core acc. to Bayka standard BayEnergy 01, resp. 02

Product Bayka Order No. Customer Order-No. Outer ∅
approx.
Net weight
approx.
Rated short-time current Max. tensile force Bending radius one-off Bending radius repeated
mm kg/km kA daN min. mm min. mm  
(N)2X     1x70 RF       CuStAl 4438500 13 600 12.65 350 90 180