Print Icon

BayRail® Signalling cables

ZPFU

…px1mm² acc. to SNCF CT 445


NT681_ZPFU_en
SNCF_infraRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung04-Rohrverlegung08-Trogverlegung44-Nagetierschutz46-Robust

 


Standards

SNCF CT 445

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor cross-section mm² 1.0
Conductor resistance Ω/km ≤ 18.1
Insulation resistance GΩxkm ≥ 5
Mutual capacitance nF/km ≤ 55
Temperature ranges °C
(acc. to DIN VDE0891, part06)
in operation
when laying, installing °C


≤ 70
-20 to +50

Design

Cu-conductor solid 1mm²
Core insulation made of polyethylene (PE)
Cores stranded in pairs
Wrapping
Inner sheath made of polyethylene (PE)
Steel tape armouring
Outer sheath made of PVC, black

Application

Railway signalling cable with armouring (rodent protection), stranded pairs, in railway control centres and surveillance systems.

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

ZPFU 14px 1mm2


Print Icon

BayRail® Signalling cables

ZPFU

…px1mm² acc. to SNCF CT 445

Product Bayka Order No. Outer ∅
approx.
Net weight
approx.
mm kg/km  
ZPFU              14px1,0 qmm     (2B0,5vz) 5783120 26 1045
Errors and omissions excepted, weights and dimensions are approximate values.