Print Icon

BayRail® Signalling cables

ZCO3

4qx1mm² (4qx1,13mm) acc. to SNCF CT 445


NT71_ZCO3_en
SNCF_infraRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung04-Rohrverlegung08-Trogverlegung40-Geschirmt44-Nagetierschutz46-Robust

 


Standards

SNCF CT 445

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm
Conductor cross-section mm²
1.13
1.0
Conductor resistance Ω/km ≤ 18.1
Insulation resistance GΩxkm ≥ 5
Mutual capacitance nF/km ≤ 40
Capacitance unbalance pF/500m (at 800 Hz) ≤ 200
Reduction factor at 50 Hz see chart

Design

Cu-conductor solid 1mm²
Core insulation made of polyethylene (PE)
Cores stranded in quads
Wrapping
1st inner sheath made of polyethylene (PE)
Screen made of corrugated copper tape, longitudinally applied
2nd inner sheath
Steel tape armouring
Outer sheath made of PVC, black

Application

Railway signalling cable, quad stranded, induction-protected with low reduction factor, for railway control centres and surveillance systems in high speed railway networks.

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

ZCO3 4qx1,0mm² (2B0,8)


Print Icon

BayRail® Signalling cables

ZCO3

4qx1mm² (4qx1,13mm) acc. to SNCF CT 445

Product Bayka Order No. Outer ∅
approx.
Net weight
approx.
Bending radius one-off Bending radius repeated
mm kg/km min. mm min. mm  
ZCO3              4qx1,0 qmm      (2B0,8) 5788120 27 1350 235 470
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.