Print Icon

BayRail® Signalling cables acc. to Swiss Federal Railways standard

SW-CLT

...x4x1,5 acc. to SBB 3001.82.1000


NT50_SW-CLT
SBB_quadratischRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung04-Rohrverlegung08-Trogverlegung10-Verlegung im Freien, UV-Schutz beachten!23-Halogenfrei26-Raucharm44-Nagetierschutz46-Robust51-Verlegung -10

 


Standards

Swiss Federal Railway SBB 3001.82.1000
halogen-free acc. to IEC 60754-1 and IEC 60754-2
smoke density acc. to IEC 61034-2

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.5
Conductor loop resistance Ω/km (DC at 20°C) ≤ 20.9
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km ≤ 52
Capacitative couplings pF/300 m at 800 Hz
k1
k9 ... k12
ea1 ... ea2

≤ 400
≤ 400
≤ 650
Operating voltage
AC Veff 16,7 Hz
DC V

500
800
Alternating voltage test Veff
Core/core
Core/armouring

2000
4000
Temperature range when laying, installing °C -10 to +50
Quad a-core
b-core
c-core
d-core
Pilot quad white orange turquoise violet
Direction quad white green turquoise violet
Standard quad 1 white white turquoise violet
Standard quad 2 white blue turquoise violet

 


 

Application

As railway signalling cable for railways, remote control, signalisation, control and safety signals.

Type Designation Codes

Solid Cu-conductor
Conductor insulation made of PE
Cores stranded to quads
Quads stranded in layers
Inner sheath made of PE, black
Steel tape armouring (CL)
Outer sheath made of PE, black (T)

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

SW-CLT 5x4x1,5 mm D


Print Icon

BayRail® Signalling cables acc. to Swiss Federal Railways standard

SW-CLT

...x4x1,5 acc. to SBB 3001.82.1000

Product Bayka Order No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
mm kg/km daN min. mm min. mm  
SW-CLT     1x4x1,5 mm D        (312-71-404) 5741205 14 220 41 120 160
SW-CLT     2x4x1,5 mm D 5741207 19 420 90 180 230
SW-CLT     3x4x1,5 mm D        (312-71-412) 5741210 20 495 120 190 250
SW-CLT     5x4x1,5 mm D        (312-71-420) 5741215 24 750 190 220 290
SW-CLT     7x4x1,5 mm D 5741220 26 935 250 240 320
SW-CLT    10x4x1,5 mm D        (312-71-440) 5741225 31 1305 350 290 380
SW-CLT    15x4x1,5 mm D        (312-71-460) 5741230 37 1835 550 330 440
SW-CLT    20x4x1,5 mm D        (312-71-480) 5741235 41 2370 730 380 500
SW-CLT    25x4x1,5 mm D        (312-71-490) 5741240 47 2955 810 430 570
SW-CLT    30x4x1,5 mm D        (312-71-495) 5741245 49 3330 900 440 590
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile stress only valid when cable sheath and cable core involved.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.