Print Icon

BayRail® Signalling cables acc. to Swiss Federal Railways standard

SW-CLT

...x4x2,2 acc. to SBB 3001.82.1000


NT50_SW-CLT
SBB_quadratischRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung04-Rohrverlegung08-Trogverlegung10-Verlegung im Freien, UV-Schutz beachten!23-Halogenfrei26-Raucharm44-Nagetierschutz46-Robust51-Verlegung -10

 


Standards

Swiss Federal Railway SBB 3001.82.1000
halogen-free acc. to IEC 60754-1 and IEC 60754-2
smoke density acc. to IEC 61034-2

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 2.2
Conductor loop resistance Ω/km (DC at 20°C) ≤ 20.9
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km ≤ 60
Capacitative couplings pF/300 m at 800 Hz
k1
k9 ... k12
ea1 ... ea2

≤ 400
≤ 400
≤ 650
Operating voltage
AC Veff 16.7 Hz
DC V

500
800
Alternating voltage test Veff
Core/core
Core/armouring

2000
4000
Temperature range when laying, installing °C -10 to +50

 

Quad a-core
b-core
c-core
d-core
Pilot quad white orange turquoise violet
Direction quad white green turquoise violet
Standard quad 1 white white turquoise violet
Standard quad 2 white blue turquoise violet


 

Application

As railway signalling cable for railways, remote control, signalisation, control and safety signals.

Type Designation Codes

Solid Cu-conductor
Conductor insulation made of PE
Cores stranded to quads
Quads stranded in layers
Inner sheath made of PE, black
Steel tape armouring (CL)
Outer sheath made of PE, black (T)

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

SW-CLT 5x4x2,2 mm D


Print Icon

BayRail® Signalling cables acc. to Swiss Federal Railways standard

SW-CLT

...x4x2,2 acc. to SBB 3001.82.1000

Product Bayka Order No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
mm kg/km daN min. mm min. mm  
SW-CLT     1x4x2,2 mm D        (312-71-604) 5741405 15 330 78 140 190
SW-CLT     3x4x2,2 mm D        (312-71-612) 5741410 25 895 240 230 310
SW-CLT     5x4x2,2 mm D        (312-71-620) 5741415 30 1320 390 270 360
SW-CLT    10x4x2,2 mm D        (312-71-640) 5741425 42 2455 780 380 510
SW-CLT    15x4x2,2 mm D        (312-71-660) 5741430 48 3490 950 440 590
SW-CLT    20x4x2,2 mm D        (312-71-680) 5741435 55 4575 1000 500 670
SW-CLT    25x4x2,2 mm D        (312-71-690) 5741440 62 5665 1200 560 750
SW-CLT    30x4x2,2 mm D        (312-71-695) 5741445 64 6425 1350 580 780
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile stress only valid when cable sheath and cable core involved.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.