Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EAPSP

EAPSP-H acc. to E. T. 03.365.051.6


NT511_EAPSP-H_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt

 


Standards

Adif E. T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance Ω/km
Mean value
Maximum value

11.2±0.5
  11.9
Insulation resistance MΩxkm  ≥ 35000
50 Hz alternating
voltage test V
Core/core
Core/screen


2100
2500

Application

Railway signalling cable, stranded cores, in railway control centres and surveillance systems.

Type Designation Codes

...H number of the single conductors
...mm conductor diameter
EA Al tape
P inner sheath made of PE
S armouring made of steel tape
P outer sheath made of PE

Order Example

19H 1,4mm EAPSP


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EAPSP

EAPSP-H acc. to E. T. 03.365.051.6

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
kg/km mm kg/km  
 4H  1,4 mm  EAPSP 5797210 59 14 225
 7H  1,4 mm  EAPSP 5797220 104 15 300
 9H  1,4 mm  EAPSP 5797230 134 18 375
12H  1,4 mm  EAPSP 5797240 178 18 430
19H  1,4 mm  EAPSP 5797250 281 21 580
27H  1,4 mm  EAPSP 5797260 393 23 760
37H  1,4 mm  EAPSP 5797270 547 24 915
48H  1,4 mm  EAPSP 5797280 709 28 1180
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.