Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EAPSP

EAPSP-PI acc. to E. T. 03.365.051.6


NT531_EAPSP-PI_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt

 


Standards

Adif E. T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor diameter Ω/km
Mean value
Maximum value

11.2±0.5
  11.9
Mutual capacitance at 1000±200 Hz nF/km
Mean value
Maximum value

59±3
  65
Near-end crosstalk attenuation dB
at 10 kHz

≥ 75
Far-end crosstalk attenuation dB
at 10 kHz

≥ 65
Insulation resistance MΩxkm ≥ 35000
50 Hz alternating
voltage test V
Core/core
Core/screen


4500
1500

Application

As a railway signalling cable, in railway control centres and surveillance systems.

Type Designation Codes

...PI number of the shielded pairs
...mm conductor diameter
EA Al tape
P inner sheath made of PE
S armouring made of steeltape
P outer sheath made of PE

Order Example

3PI 0,9mm EAPSP


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EAPSP

EAPSP-PI acc. to E. T. 03.365.051.6

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
kg/km mm kg/km  
 6PI 1,4 mm  EAPSP 5797535 188 29 715
10PI 1,4 mm  EAPSP 5797560 314 33 955
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.