Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EATST

EATST-H acc. to E. T. 03.365.051.6


NT551_EATST-H_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt23-Halogenfrei24-Flammwidrig26-Raucharm

 


Standards

adif E.T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance Ω/km
Mean value
Maximum value

11.2±0.5
  11.9
Insulation resistance MΩxkm ≥ 35000
50 Hz alternating voltage test
Core/core
Core/screen

2100
2500

Application

Railway signalling cable, stranded cores, in railway control centres and surveillance systems.

Type Designation Codes

...H number of the single conductors
...mm conductor diameter
EA Al tape
T inner sheath made of halogen-free, flame retardant copolymer
S armouring made of steel tape
T outer sheath made of halogen-free, flame retardant copolymer

Order Example

19H 1,4mm EAPSP


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EATST

EATST-H acc. to E. T. 03.365.051.6

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
kg/km mm kg/km  
19H  1,4 mm  EATST 5797251 276 19 615
37H  1,4 mm  EATST 5797271 539 24 1020
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.