Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EATST

EATST-P acc. to E. T. 03.365.051.6


NT561_EATST-P_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt23-Halogenfrei24-Flammwidrig26-Raucharm

 


Standards

Adif E. T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0,64 0.9 1,3 1,4
Conductor resistance Ω/km
Mean value
Maximum value


54,5±2,0
  58,0


27.5±1.0
  29.0



13,2±0,5
  13,9



11.2±0,5
  11,9
Mutual capacitance at
1000±200Hz nF/km
Mean value
Max. value


52±4
  58


52±4
  58


52±4
  58


52±4
  58
Capacitance
difference
at 1000±200 Hz
pF/km
Pair-pair mean
Pair-pair max.
Pair-earth mean
Pair-earth max.




45
260
650
2625




45
260
650
2625




45
260
650
2625




45
260
650
2625
Attenuation at 1 MHz dB/km ≤ 17,5 < 12.8 ≤ 8,62  
Insulation resistance MΩxkm ≥ 35000 ≥ 35000 ≥ 35000 ≥ 35000
50 Hz alternating
voltage test V
Core/core
Core/screen


2100
2500


2100
2500


2100
2500


2100
2500

Application

As a railway signalling cable, in railway control centres and surveillance systems.

Type Designation Codes

...P number of the pairs
...mm conductor diameter
T inner sheath made of halogen-free, flame retardant copolymer
S armouring made of steel tape
T outer sheath made of halogen-free, flame retardant copolymer

Order Example

1P 0,9mm EAPSP


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EATST

EATST-P acc. to E. T. 03.365.051.6

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
kg/km mm kg/km  
There are no items in your cart.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.