Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EATST

EATST-X acc. to E. T. 03.365.051.6


NT581_EATST-x_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt23-Halogenfrei24-Flammwidrig26-Raucharm

 


Standards

Adif E. T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.9 1.3 1.4
Conductor resistance Ω/km
Mean value
Maximum value

27.5±1
  29.0

13.2±0.5
 13.9

11.2±0.5
  11.9
Mutual capacitance at 1000±200 Hz nF/km
Mean value
Maximum value

38±3
  45

41±4
  48

41±4
  48
Capacitance difference
at 1000±200 Hz pF/km
Pair-pair mean value
Pair-pair maximum value
Pair-earth mean value
Pair-earth maximum value


35
250
320
1200


35
250
320
1200


35
250
320
1200
Attenuation at 1000 Hz dB/km ≤ 0.7 ≤ 0.5 ≤ 0.46
Insulation resistance MΩxkm ≥ 35000 ≥ 35000 ≥ 35000
50 Hz alternating
voltage test V
Core/core
Core/screen


2100
2500


2100
2500


2100
2500

Application

As a railway signalling cable, in railway control centres and surveillance systems.

Type Designation Codes

...X number of the quads
...mm conductor diameter
EA Al tape
T inner sheath made of halogen-free, flame retardant copolymer
S armouring made of steel tape
T outer sheath made of halogen-free, flame retardant copolymer

Order Example

3X 0,9mm EAPSP


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

EATST

EATST-X acc. to E. T. 03.365.051.6

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
kg/km mm kg/km  
There are no items in your cart.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.