Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

CCPSSP

CCPSSP-H acc. to E. T. 03.365.051.6


NT591_CCPSSP-H_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt46-Robust44-Nagetierschutz

 


Standards

Adif E. T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance (pair of cores) Ω/km
Mean value
Maximum value

11.2±0.5
  11.9
Insulation resistance MΩxkm ≥ 35000
50 Hz alternating voltage test
Core-core Veff
Core-screen Veff

2100
2500

Application

Railway signalling cable, stranded cores, in railway control centres and surveillance systems.

Type Designation Codes

...H number of the single conductors
...mm conductor diameter
CC screen made of copper wires or tapes
P inner sheath made of PE (optional)
SS armouring made of steel tapes
P outer sheath made of PE
FR reduction factor characteristic

Order Example

19H 1,4mm CCPSSP FR 0,3


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

CCPSSP

CCPSSP-H acc. to E. T. 03.365.051.6

Product Bayka Order No. Outer ∅
approx.
Net weight
approx.
mm kg/km  
 4H  1,4 mm  CCPSSP    FR 0,3 5796210 18 575
 7H  1,4 mm  CCPSSP    FR 0,3 5796220 18 595
 9H  1,4 mm  CCPSSP    FR 0,3 5796230 20 700
12H  1,4 mm  CCPSSP    FR 0,3 5796240 20 760
19H  1,4 mm  CCPSSP    FR 0,3 5796250 22 945
27H  1,4 mm  CCPSSP    FR 0,3 5796260 25 1155
37H  1,4 mm  CCPSSP    FR 0,3 5796270 27 1365
48H  1,4 mm  CCPSSP    FR 0,3 5796280 30 1670
Errors and omissions excepted, weights and dimensions are approximate values.