Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

CCTSST

CCTSST-H acc. to E. T. 03.365.051.6


NT631_CCTSST-H_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt23-Halogenfrei24-Flammwidrig26-Raucharm46-Robust44-Nagetierschutz

 


Standards

adif E.T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance (pair of cores) Ω/km
Mean value
Maximum value

11.2±0.5
  11.9
Insulation resistance MΩxkm ≥ 35000
50 Hz alternating voltage test
Core-core Veff
Core-screen Veff

2100
2500

Application

Railway signalling cable, stranded cores, in railway control centres and surveillance systems.

Type Designation Codes

 

...H number of single conductors
...mm conductor diameter
CC screen made of copper wires or tapes
T inner sheath made of halogen-free, flame retardant copolymer (optional)
SS armouring made of steel tapes
T outer sheath made of halogen-free, flame retardant copolymer
FR reduction factor characteristic

 

Order Example

19H 1,4mm CCTSST FR 0,3


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

CCTSST

CCTSST-H acc. to E. T. 03.365.051.6

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
kg/km mm kg/km  
 7H  1,4 mm  CCTSST    FR 0,3 5796221 160 17 655
12H  1,4 mm  CCTSST    FR 0,3 5796241 251 20 830
19H  1,4 mm  CCTSST    FR 0,3 5796251 361 22 1025
27H  1,4 mm  CCTSST    FR 0,3 5796261 488 24 1255
37H  1,4 mm  CCTSST    FR 0,3 5796271 653 26 1480
48H  1,4 mm  CCTSST    FR 0,3 5796281 829 30 1805
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.