Download IconPrint Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

CCTSST

CCTSST-PI acc. to E. T. 03.365.051.6


NT651_CCTSST-PI_en
ADIFRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!40-Geschirmt23-Halogenfrei24-Flammwidrig26-Raucharm46-Robust44-Nagetierschutz

 


Standards

Adif E. T. 03.365.051.6

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance Ω/km
Mean value
Maximum value

11.2±0.5
  11.9
Mutual capacitance at 1000±200 Hz nF/km
Mean value
Maximum value

59±3
  65
Near-end crosstalk attenuation dB
at 10 kHz

≥ 75
Far-end crosstalk attenuation dB
at 10 kHz

≥ 65
Insulation resistance MΩxkm ≥ 35000
50 Hz alternating voltage test
Core-core Veff 2,500
Core-screen Veff

4500
1500

Application

As a railway signalling cable, in railway control centres and surveillance systems.

Type Designation Codes

...PI number of pairs in foil
...mm conductor diameter
CC screen made of copper wires or tapes
T inner sheath made of halogen-free, flame retardant copolymer (optional)
SS armouring made of steel tapes
T outer sheath made of halogen-free, flame retardant copolymer
FR reduction factor characteristic

Order Example

3PI 0,9mm CCTSST FR 0,3


Print Icon

BayRail® signalling cables acc. to RENFE/ADIF standard

CCTSST

CCTSST-PI acc. to E. T. 03.365.051.6

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
kg/km mm kg/km  
 6PI 1,4 mm  CCTSST    FR 0,3 5793531 360 33 1490
10PI 1,4 mm  CCTSST    FR 0,3 5793561 528 35 1820
14PI 1,4 mm  CCTSST    FR 0,3 5793581 697 39 2260
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.