Print Icon

BayRail® Line conductor cables for the LZB system

A-2Y(ZG)2Y
A-H(ZG)H

LZB Line conductor cable acc. to DB TL 416.0101


NT423_A-2Y(ZG)2Y_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

10-Verlegung im Freien, UV-Schutz beachten!20-UV-beständig50-Verlegung -5

optional

Halogenfrei optionalFlammwidrig optionalRaucharm optional

Standards

Technical specifications 416.0101,
Bayka BayRail company standard.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 2
Conductor resistance Ω/km ≤9
Alternating voltage test 50 Hz  
Core-Core Veff 2500
Temperature ranges  
During laying, installing °C -5 to +50
Before and after laying, installing °C -40 to +70

Application

Line conductor cable for the LZB (continuous train control) system. The standard design, A-2Y(ZG)2Y, is for laying on free sections, and the flame-retardant FRNC design, A-H(ZG)H, is for laying in tunnels.

Type Designation Codes

A outdoor cable
2Y  conductor insulation made of polyethylene (PE)
H conductor insulation made of halogen-free material
(ZG) non-metallic stress relief elements in the PE sheath
2Y outer sheath made of PE
H outer sheath made of halogen-free material

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

Linienleiterkabel A-2Y(ZG)2Y 1x2 mm²


Print Icon

BayRail® Line conductor cables for the LZB system

A-2Y(ZG)2Y
A-H(ZG)H

LZB Line conductor cable acc. to DB TL 416.0101

Product Bayka Order No. Customer Order-No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2Y(ZG)2Y    1x2 mm²          Linienleiter-Kabel  (00129018) 5730000 00129018 20 13 150 400 100 130
A-H(ZG)H     1x2 mm²           Linienleiter-Kabel 5799000 20 12 245 400 100 130
Tensile stress only valid when cable sheath and cable core involved.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.