BayRail® Signalling cables, quad stranded, (H45)

A-2Y(L)2YB2Y

...x4x1,4 acc. to DB TL 416.0115


NT31_A-2Y(L)2YB2Y_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!38-Querwasserdicht40-Geschirmt44-Nagetierschutz46-Robust51-Verlegung -10

 


Standards

Technical specifications 416.0115,
Engineering specifications 416.0116,
Bayka BayRail company standard.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance (pair of cores) Ω/km ≤ 23.4
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km ≤ 45
For the central quad nF/km ≤ 50
Alternating voltage test 50 Hz  
Core-core Veff 2500
Core-screen Veff 2500
Temperature ranges  
During laying, installing °C -10 to +60
Before and after laying, installing °C -40 to +60

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

Type Designation Codes

A outdoor cable
2Y insulating cover made of polyethylene (PE)
(L)2Y laminated sheath made of polyethylene, reinforced
B armouring
2Y outer sheath made of PE
S signalling cable
(H45) maximum mutual capacitance value at 800 Hz, 45 nF/km

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-2Y(L)2YB2Y 10x4x1,4 S (H45)


Print Icon

BayRail® Signalling cables, quad stranded, (H45)

A-2Y(L)2YB2Y

...x4x1,4 acc. to DB TL 416.0115

Product Bayka Order No. Customer Order-No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2Y(L)2YB2Y        1x4x1,4 S   416.0115  (00649993) 5780400 00649993 63 14 260 35 105 140
A-2Y(L)2YB2Y        3x4x1,4 S   416.0115  (00649994) 5780600 00649994 186 21 570 101 155 210
A-2Y(L)2YB2Y        5x4x1,4 S   416.0115  (00649995) 5780700 00649995 310 24 820 164 180 240
A-2Y(L)2YB2Y        7x4x1,4 S   416.0115  (00649996) 5780800 00649996 437 26 1020 226 195 260
A-2Y(L)2YB2Y       10x4x1,4 S   416.0115  (00736107) 5718600 00736107 621 33 1320 308 240 320
A-2Y(L)2YB2Y       14x4x1,4 S   416.0115  (00996931) 5782700 00996931 868 37 1550 412 280 370
A-2Y(L)2YB2Y       20x4x1,4 S   416.0115  (00996932) 5782710 00996932 1237 42 2160 563 315 420
A-2Y(L)2YB2Y       30x4x1,4 S   416.0115  (00996933) 5723460 00996933 1853 49 3060 781 370 490
A-2Y(L)2YB2Y       40x4x1,4 S   416.0115  (00996934) 5723462 00996934 2469 54 3910 963 420 560
Tensile stress only valid when cable sheath and cable core involved.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.