Download IconPrint Icon

BayRail® Signalling cables, core-stranded, filled, (H115) / (H145)

A-2YOF(L)2YB2Y

...x1x0,9 acc. to DB TL 416.0113 (since 2007)


NT14_A-2YOF(L)2YB2Y_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!36-Längswasserdicht38-Querwasserdicht40-Geschirmt44-Nagetierschutz46-Robust51-Verlegung -10

 


Standards

Technical specifications 416.0113,
Engineering specifications 416.0116,
Bayka BayRail company standard.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.9
Conductor resistance Ω/km ≤ 28.9
Insulation resistance GΩxkm ≥ 1.5
Mutual capacitance at 800 Hz nF/km
For the central core nF/km
≤ 115
≤ 120
Alternating voltage test 50 Hz
Core-core Veff

2500
Operating voltage peak value
Direct current V
Alternating current Veff

≤ 600
≤ 420
Temperature range °C
During laying, installing
Before and after laying, installing

-10 to +60
-40 to +60

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

The cables are longitudinally watertight due to low capacitance filling material and transversally watertight due to a multi-layer sheath.

Type Designation Codes

A outdoor cable
2Y insulating cover made of polyethylene (PE)
OF filling of the cabled assembly with low capacitance filling material
(L)2Y laminated sheath made of polyethylene
B armouring
2Y outer protective sheath made of PE
S signalling cable
(H115) maximum mutual capacitance value at 800 Hz, 115 nF/km

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-2YOF(L)2YB2Y 50x1x0,9 S (H115)


Print Icon

BayRail® Signalling cables, core-stranded, filled, (H115) / (H145)

A-2YOF(L)2YB2Y

...x1x0,9 acc. to DB TL 416.0113 (since 2007)

Product Bayka Order No. Customer Order-No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2YOF(L)2YB2Y       2x1x0,9 S (H115) 416.0113 (00996869) 5745749 00996869 13 13 160 25 100 130
A-2YOF(L)2YB2Y       4x1x0,9 S (H115) 416.0113 (00996870) 5745750 00996870 25 13 170 25 110 130
A-2YOF(L)2YB2Y       7x1x0,9 S (H115) 416.0113 (00996871) 5745754 00996871 45 14 220 30 105 140
A-2YOF(L)2YB2Y      10x1x0,9 S (H115) 416.0113 (00996872) 5745756 00996872 64 17 290 38 130 170
A-2YOF(L)2YB2Y      14x1x0,9 S (H115) 416.0113 (00996873) 5745758 00996873 89 17 300 51 130 170
A-2YOF(L)2YB2Y      20x1x0,9 S (H115) 416.0113 (00996874) 5745760 00996874 127 18 380 72 135 180
A-2YOF(L)2YB2Y      24x1x0,9 S (H115) 416.0113 (00996875) 5745762 00996875 153 20 460 84 150 200
A-2YOF(L)2YB2Y      30x1x0,9 S (H115) 416.0113 (00996876) 5745764 00996876 191 20 490 106 150 200
A-2YOF(L)2YB2Y      40x1x0,9 S (H115) 416.0113 (00996877) 5745766 00996877 254 21 590 140 160 210
A-2YOF(L)2YB2Y      50x1x0,9 S (H115) 416.0113 (00996878) 5745768 00996878 318 23 700 172 175 230
A-2YOF(L)2YB2Y      60x1x0,9 S (H115) 416.0113 (00996879) 5745770 00996879 382 25 800 203 190 250
A-2YOF(L)2YB2Y      80x1x0,9 S (H115) 416.0113 (00996880) 5745772 00996880 509 26 1000 266 195 260
A-2YOF(L)2YB2Y     100x1x0,9 S (H115) 416.0113 (00996881) 5745774 00996881 636 31 1250 320 235 310
A-2YOF(L)2YB2Y     120x1x0,9 S (H115) 416.0113 (00996882) 5745776 00996882 763 32 1390 383 240 320
A-2YOF(L)2YB2Y     140x1x0,9 S (H115) 416.0113 (00996883) 5745778 00996883 891 35 1650 432 265 350
A-2YOF(L)2YB2Y     160x1x0,9 S (H115) 416.0113 (00996884) 5745780 00996884 1018 36 1790 491 270 360
A-2YOF(L)2YB2Y     180x1x0,9 S (H115) 416.0113 (00996885) 5745782 00996885 1145 39 2030 536 295 390
A-2YOF(L)2YB2Y     200x1x0,9 S (H115) 416.0113 (00996886) 5745784 00996886 1272 39 2150 597 295 390
Tensile stress only valid when cable sheath and cable core involved.
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Errors and omissions excepted, weights and dimensions are approximate values.