BayRail® Signalling cables, quad and core-stranded
A-2Y(L)2Y2YV / A-2Y(L)2Y2YB2Y / AJ-2Y(L)2Y2YDB2Y
...x1x0,9/1,4/1,8 acc. to DB TL 416.0118














Standards
Technical specifications 416.0118,
Bayka BayRail company standard.
The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2011/65/EU - RoHS 2.0 and Regulation No. 1907/2006 (REACH).
Technical Data
Conductor diameter mm | 0.9 | 1.4 | 1.8 |
Single conductors |
|||
Conductor resistance Ω/km | ≤ 28.9 | ≤ 11.9 | ≤ 7.2 |
Insulation resistance GΩxkm | ≥ 10 | ≥ 10 | ≥ 10 |
Mutual capacitance at 800 Hz nF/km | ≤ 120 | ≤ 120 | ≤ 120 |
Quads |
|||
Conductor loop resistance Ω/km | ≤ 56.6 | ≤ 23.4 | |
Insulation resistance GΩxkm | ≥ 10 | ≥ 10 | |
Mutual capacitance at 800 Hz nF/km | ≤ 45 | ≤ 45 | |
For 1x4, 3x4, and/or central quad (in the first layer, only 1 quad), ≤ 52 nF applies |
|||
Capacitative couplings at 800 Hz pF/500m | |||
K1 | ≤ 650 | ≤ 650 | |
C9-12 neighbouring quads | ≤ 500 | ≤ 500 | |
C9-12 quads next to neighbouring quads | ≤ 150 | ≤ 150 | |
ea1/2 | ≤ 1300 | ≤ 1300 | |
Surge impedance at 40 kHz Ω |
130 ±12 % |
130 ±12 % |
|
Wave attenuation at 40 kHz dB/km | ≤ 2.6 | ≤ 1.5 | |
Near-end crosstalk attenuation at 40 kHz (average value/min. single value) dB |
|||
In the quad | ≥65/60 | ≥65/60 | |
Neighbouring quads | ≥65/60 | ≥65/60 | |
Quads next to neighbouring quads | ≥70/60 | ≥70/60 | |
Quads in neighbouring layer | ≥75/65 | ≥75/65 | |
Alternating voltage test 50 Hz | |||
Core/core, core/screen Veff | 2500 | ||
Temperature ranges | |||
During laying, installing °C | -10 to +60 | ||
Before and after laying, installing °C | -40 to +60 |
Application
As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.
The combined signalling cables are suitable
- for special use in safety installations
- for energy transfer in a cable, especially when, for the star quads, high symmetry with one another is required against external interferences and against earth potential, as is called for by AF and digital transmission.
- for transmission of direct current at an operating voltage of ≤ 600 V or of alternating currents ≤ 420 Veff.
- for especially long railway control distances during low-frequency (AF) or digital transmission.
- for earthing the cable screen on both sides according to the relevant requirements of DB AG.
The cables should be used where they provide benefits in a technical and/or economical sense.
Type Designation Codes
A | outdoor cable |
AJ | outdoor cable with inductive protection |
2Y | conductor insulation, sheath made of PE |
(L)2Y | laminated sheath made of polyethylene |
D | screen made of copper wires |
B | armouring |
2YV | outer sheath made from PE, reinforced |
S | signalling cable |
rk | reduction factor characteristic |
Order Example
AJ-2Y(L)2Y2YDB2Y 1x4x0,9 + 4x1x1,4 S
BayRail® Signalling cables, quad and core-stranded
A-2Y(L)2Y2YV / A-2Y(L)2Y2YB2Y / AJ-2Y(L)2Y2YDB2Y
...x1x0,9/1,4/1,8 acc. to DB TL 416.0118
The bending radius for repeated bending applies to the radius of switching mechanisms, too.
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
*) N/A (not applicable) Cable is not subject to the Construction Products Regulation CPR