Download IconPrint Icon

BayRail® Signalling cables, quad stranded, screened, armoured, PVC sheath

A-2Y(St)YbY

...x4x1,4 acc. to DB Dlk 1.013.201y


NT35_en
DB_LogoVDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!38-Querwasserdicht40-Geschirmt44-Nagetierschutz46-Robust50-Verlegung -5

 


Standards

Dlk 1.013.201y and/or DIN VDE 0816-part 2.

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance Ω/km ≤ 23.4
Insulation resistance GΩxkm ≥ 5
Mutual capacitance at 800 Hz nF/km ≤ 50
Capacitive couplings pF for 300 m at 800 Hz
K1 ≤ 400
K9-12 ≤ 300
Alternating voltage test 50 Hz  
Core-core Veff 2500
Core-screen Veff 2500
Temperature range  
During laying, installing °C -5 to +50
Before and after laying, installing °C -30 to +70

Application

As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.

Type Designation Codes

A outdoor cable
2Y core insulation made of PE
(St) static screen
Y inner sheath made of PVC
b armouring
Y outer sheath made of PVC
S signalling cable
(H50) maximum mutual capacitance value at 800 Hz, 50 nF/km

Additional Informations

Design according to national and international standards
Design according to customer specifications
Design with improved electrical properties
Flame retardant, non corrosive cables (FRNC, LSOH)

Order Example

A-2Y(St)YbY 10x4x1,4 S (H50) (1B 0,3)


Print Icon

BayRail® Signalling cables, quad stranded, screened, armoured, PVC sheath

A-2Y(St)YbY

...x4x1,4 acc. to DB Dlk 1.013.201y

Product CPR DoP *) Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-2Y(St)YbY       1x4x1,4 S Lg   (1B 0.3)          (00128970) N/A 5772100 101 17.5 460 30 160 240
A-2Y(St)YbY       3x4x1,4 S Lg   (1B 0.3)          (00128971) N/A 5772300 250 25 885 90 200 300
A-2Y(St)YbY       5x4x1,4 S Lg   (1B 0.3)          (00128972) N/A 5772400 384 28 1140 145 232 348
A-2Y(St)YbY       5x4x1,4 S Lg   (1B 0.3) N/A 5772600 384 28 1070 145 232 348
A-2Y(St)YbY       7x4x1,4 S Lg   (1B 0.3)          (00128973) N/A 5772700 536 32 1455 200 175 350
A-2Y(St)YbY      10x4x1,4 S Lg   (1B 0.3)          (00128974) N/A 5773000 743 37.5 1940 270 296 444
A-2Y(St)YbY      14x4x1,4 S Lg   (1B 0.3)          (00128975) N/A 5773200 1004 41 2375 370 328 492
A-2Y(St)YbY      20x4x1,4 S Lg   (1B 0.3)          (00128976) N/A 5773400 1391 46.5 3125 510 368 552
A-2Y(St)YbY      30x4x1,4 S Lg   (1B 0.3) N/A 5748000 2041 55 4325 730 456 684
The cable is for installation in the ground or outside structures and is therefore not subject to the CPR. It cannot be classified as Eca or better.