BayRail® Signalling cables, core-stranded, flame retardant, non corrosive, FRNC/LSOH

A-HHV

...x1x0,9 acc. to Bayka standard, based on DB Dlk 1.013.102y


NT90_A-HHV_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!23-Halogenfrei24-Flammwidrig26-Raucharm51-Verlegung -10

 


Standards

Bayka company standard BayRail®,
electrical properties based on Dlk 1.013.102y,
flame propagation according to DIN VDE 0472, part 804, test method C,
smoke density according to DIN VDE 0482, part 1034-2 (EN61034-2),
corrosivity of fire gases according to DIN VDE 0482, part 267-2-2 (EN 50267-2-2),
toxicity according to DIN VDE 0260, part 305 (EN50305), limit based on EN50306-1, 2 and 3 for hazard level: max. 5 (for insulation, extruded sheath, reinforcing outer sheath).

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.9
Conductor resistance Ω/km ≤ 28.9
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km
For core(s) in the inner layer nF/km
≤ 105
≤ 110
Alternating voltage test 50 Hz
Core-core Veff
Core-screen Veff

2500
2500
Temperature ranges °C
During laying, installing
Before and after laying, installing

-10 to +60
-40 to +60

Integrated monitoring cores from 10x1 on

Application

Signalling cable, optimised for installation, transversally watertight, flame-retardant for railway control centres and surveillance systems, etc., suitable for installation in open air, in the ground, in cable tray channels, and for laying in tunnels and buildings.

The cable is halogen-free, flame-retardant, and with low smoke density, and therefore suitable for installation in areas with special hazards caused by fire propagation.

VDE approved and system-tested sleeves and conduits are available for this cable.

Type Designation Codes

A outdoor cable
H core insulation halogen-free
Hv outer sheath, reinforced, halogen-free, flame-retardant,
cable with improved behaviour in the event of fire
S signalling cable
LG stranded in layers

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-HHV 200 x 1 x 0,9 S LG (H105)


Print Icon

BayRail® Signalling cables, core-stranded, flame retardant, non corrosive, FRNC/LSOH

A-HHV

...x1x0,9 acc. to Bayka standard, based on DB Dlk 1.013.102y

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-HHV      4x1x0,9 S Lg (H105) (M-SW) 5770820 26 13 200 12 70 140
A-HHV      7x1x0,9 S Lg (H105) (M-SW) 5770830 45 14 230 22 75 150
A-HHV      8x1x0,9 S Lg (H105) (M-SW) 5770832 51 14 245 24 75 150
A-HHV     12x1x0,9 S Lg (H105) (M-SW) 5770840 80 15 300 36 80 160
A-HHV     14x1x0,9 S Lg (H105) (M-SW) 5770843 93 16 315 44 80 160
A-HHV     20x1x0,9 S Lg (H105) (M-SW) 5770845 132 18 390 73 90 180
A-HHV     24x1x0,9 S Lg (H105) (M-SW) 5770850 157 18 420 86 100 200
A-HHV     30x1x0,9 S Lg (H105) (M-SW) 5770860 195 19 485 107 100 200
A-HHV     40x1x0,9 S Lg (H105) (M-SW) 5770865 259 20 590 141 110 220
A-HHV     48x1x0,9 S Lg (H105) (M-SW) 5770866 305 21 660 167 115 230
A-HHV     50x1x0,9 S Lg (H105) (M-SW) 5770867 323 22 680 174 120 240
A-HHV     60x1x0,9 S Lg (H105) (M-SW) 5770870 386 23 775 206 125 250
A-HHV     80x1x0,9 S Lg (H105) (M-SW) 5771050 513 25 960 270 135 270
A-HHV     96x1x0,9 S Lg (H105) (M-SW) 5770880 611 26 1105 310 0 0
A-HHV    133x1x0,9 S Lg (H105) (M-SW) 5770890 846 30 1425 420 155 310
A-HHV    200x1x0,9 S Lg (H105) (M-SW) 5770900 1277 35 2025 608 0 0
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.