Print Icon

BayRail® Signalling cables, core-stranded, armoured, flame retardant, non corrosive, FRNC/LSOH

A-HHBH

...x1x0,9 acc. to Bayka standard, based on DB Dlk 1.013.102y


NT91_A-HHBH_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!38-Querwasserdicht23-Halogenfrei24-Flammwidrig26-Raucharm46-Robust44-Nagetierschutz51-Verlegung -10

 


Standards

Bayka company standard BayRail®,
electrical properties based on Dlk 1.013.102y,
flame propagation according to DIN VDE 0472, part 804, test method C,
smoke density according to DIN VDE 0482, part 1034-2 (EN61034-2),
corrosivity of fire gases according to DIN VDE 0482, part 267-2-2 (EN 50267-2-2),
toxicity according to DIN VDE 0260, part 305 (EN50305), limit based on EN50306-1, 2 and 3 for hazard level: max. 5 (for insulation, inner sheath, outer sheath).

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 0.9
Conductor resistance Ω/km ≤ 28.9
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km
For core(s) in the inner layer nF/km
≤ 105
≤ 110
Alternating voltage test 50 Hz
Core-core Veff
Core-screen Veff

2500
2500
Temperature ranges °C
During laying, installing
Before and after laying, installing

-10 to +60
-40 to +60

Integrated monitoring cores from 10x1 on

Application

Signalling cable, optimised for installation, transversally watertight, flame-retardant and rodent-proof for railway control centres and surveillance systems, etc., suitable for installation in open air, in the ground, in cable tray channels, and for laying in tunnels and buildings.

The cable is halogen-free, flame-retardant, and with low smoke density, and therefore suitable for installation in areas with special hazards caused by fire propagation.

VDE approved and system-tested sleeves and conduits are available for this cable.

Type Designation Codes

A outdoor cable
H conductor insulation, halogen-free
H inner sheath, halogen-free
B armouring, 2 layers, steel tape 0.1 or 0.2 mm
H outer sheath, halogen-free, frame-retardant
S signalling cable
LG stranded in layers

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-HHBH 12 x 1 x 0,9 S LG (H105)


Print Icon

BayRail® Signalling cables, core-stranded, armoured, flame retardant, non corrosive, FRNC/LSOH

A-HHBH

...x1x0,9 acc. to Bayka standard, based on DB Dlk 1.013.102y

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-HHBH       4x1x0,9 S (H 105) (M-SW) 5741250 26 12 210 12 100 130
A-HHBH       7x1x0,9 S (H 105) (M-SW) 5741260 45 14 270 22 110 140
A-HHBH      10x1x0,9 S (H 105) (M-SW) 5741300 64 15 320 31 120 150
A-HHBH      14x1x0,9 S (H 105) (M-SW) 5741305 93 15 355 44 120 160
A-HHBH      20x1x0,9 S (H 105) (M-SW) 5741310 132 17 430 63 130 170
A-HHBH      24x1x0,9 S (H 105) (M-SW) 5741312 157 18 480 76 140 180
A-HHBH      30x1x0,9 S (H 105) (M-SW) 5741314 195 19 535 95 140 190
A-HHBH      40x1x0,9 S (H 105) (M-SW) 5741315 259 20 640 127 160 210
A-HHBH      48x1x0,9 S (H 105) (M-SW) 5741320 323 22 780 153 170 220
A-HHBH      50x1x0,9 S (H 105) (M-SW) 5741317 323 22 800 159 170 230
A-HHBH      60x1x0,9 S (H 105) (M-SW) 5741319 386 23 900 190 180 240
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.