Print Icon

BayRail® Signalling cables, quad stranded, armoured, flame retardant, non corrosive, FRNC/LSOH

A-H(L)HBH

...x4x0,9 acc. to Bayka standard, based on DB Dlk 1.013.201y


NT93_A-H(L)HBH_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!38-Querwasserdicht40-Geschirmt23-Halogenfrei24-Flammwidrig26-Raucharm46-Robust44-Nagetierschutz51-Verlegung -10

 


Standards

Bayka company standard BayRail®,
electrical properties based on Dlk 1.013.201y,
flame propagation according to DIN VDE 0472, part 804, test method C,
smoke density according to DIN VDE 0482, part 1034-2 (EN61034-2),
corrosivity of fire gases according to DIN VDE 0482, part 267-2-2 (EN 50267-2-2),
toxicity according to DIN VDE 0260, part 305 (EN50305), limit based on EN50306-1, 2 and 3 for hazard level: max. 5 (for insulation, inner sheath, outer sheath).

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

 

Technical Data

Conductor diameter mm 0.9
Conductor resistance (pair of cores) Ω/km ≤ 56.6
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km ≤ 45
Capacitive couplings pF
(for 300 m at 800 Hz)
k1
k9-12 neighbouring/next to neighbouring


≤ 400
≤ 300/100
Alternating voltage test 50 Hz
Core-core Veff
Core-screen  Veff

2500
2500
Temperature ranges °C
During laying, installing
Before and after laying, installing

-10 to +60
-40 to +60

Integrated monitoring cores from 5x4 on

Application

Signalling cable, optimised for installation, transversally watertight, flame-retardant for railway control centres and surveillance systems, etc., suitable for installation in open air, in the ground, in cable tray channels, and for laying in tunnels and buildings.

The cable is halogen-free, flame-retardant, and with low smoke density, and therefore suitable for installation in areas with special hazards caused by fire propagation.

VDE approved and system-tested sleeves and conduits are available for this cable.

 

Type Designation Codes

A outdoor cable
H conductor insulation, halogen-free
(L)H inner sheath, halogene-free, with Al tape
B armouring, 2 layers, steel tape 0.1 or 0.2 mm
H outer sheath, halogen-free, frame-retardant
S signalling cable
Lg stranded in layers

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-H(L)HBH 7 x 4 x 0,9 S LG (H45)


Print Icon

BayRail® Signalling cables, quad stranded, armoured, flame retardant, non corrosive, FRNC/LSOH

A-H(L)HBH

...x4x0,9 acc. to Bayka standard, based on DB Dlk 1.013.201y

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-H(L)HBH    1x4x0,9 S  (H 45) (M-SW) 5771210 27 14 270 15 115 150
A-H(L)HBH    3x4x0,9 S  (H 45) (M-SW) 5771211 78 19 430 43 145 190
A-H(L)HBH    5x4x0,9 S  (H 45) (M-SW) 5771212 129 21 560 71 160 210
A-H(L)HBH    4x4x0,9 S  (H 45) (M-SW) 5771209 108 20 510 57 160 210
A-H(L)HBH    7x4x0,9 S  (H 45) (M-SW) 5771213 184 22 650 98 175 230
A-H(L)HBH   10x4x0,9 S  (H 45) (M-SW) 5771214 260 25 820 136 195 260
A-H(L)HBH   14x4x0,9 S  (H 45) (M-SW) 5771215 362 29 1080 186 220 290
A-H(L)HBH   20x4x0,9 S  (H 45) (M-SW) 5771216 515 31 1370 270 240 320
A-H(L)HBH   30x4x0,9 S  (H 45) (M-SW) 5771217 769 37 1870 380 285 380
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.