Print Icon

BayRail® Signalling cables, quad stranded, flame retardant, non corrosive, FRNC/LSOH

A-H(St)HV

...x4x1,4 acc. to Bayka standard, based on DB Dlk 1.013.201y


NT92_A-H(ST)HV_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!38-Querwasserdicht23-Halogenfrei24-Flammwidrig26-Raucharm51-Verlegung -10

 


Standards

Bayka company standard BayRail®,
electrical properties based on Dlk 1.013.201y,
flame propagation according to DIN VDE 0472, part 804, test method C,
smoke density according to DIN VDE 0482, part 1034-2 (EN61034-2),
corrosivity of fire gases according to DIN VDE 0482, part 267-2-2 (EN 50267-2-2),
toxicity according to DIN VDE 0260, part 305 (EN50305), limit based on EN50306-1, 2 and 3 for hazard level: max. 5 (for insulation, extruded sheath, reinforcing outer sheath).

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance (pair of cores) Ω/km ≤ 23.4
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km ≤ 45
Capacitative couplings at 800 Hz pF/300m
k1
k9-12 neighbouring/next to neighbouring

≤ 400
≤ 300/100
Alternating voltage test 50 Hz
Core-core Veff
Core-screen  Veff

2500
2500
Temperature ranges °C
During laying, installing
Before and after laying, installing

-10 to +60
-40 to +60

Application

Signalling cable, optimised for installation, transversally watertight, flame-retardant and rodent-proof for railway control centres and surveillance systems, etc., suitable for installation in open air, in the ground, in cable tray channels, and for laying in tunnels and buildings.

The cable is halogen-free, flame retardant and with low smoke density. It is suitable for installation in tunnels and in areas with special hazards caused by fire propagation.

VDE approved and system-tested sleeves are available for this cable.

Type Designation Codes

A outdoor cable
H conductor insulation, halogen-free
(ST) static screen (Cu tape)
HV
outer sheath, reinforced, halogen-free, flame-retardant
S signalling cable
LG quads stranded in layers
(H45) maximum mutual capacitance value at 800 Hz
(M-SW)
outer sheath, black
(M-BL)
outer sheath, blue

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-H(St)Hv 1 x 4 x 1,4 S Lg (H45) (M-SW)


Print Icon

BayRail® Signalling cables, quad stranded, flame retardant, non corrosive, FRNC/LSOH

A-H(St)HV

...x4x1,4 acc. to Bayka standard, based on DB Dlk 1.013.201y

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius repeated Bending radius one-off
kg/km mm kg/km daN min. mm min. mm  
A-H(St)HV   1x4x1,4 S Lg (H45) (M-SW) 5739250 101 16 310 36 160 80
A-H(ST)HV   3x4x1,4 S Lg (H45) (M-SW) 5739300 245 22 560 103 220 110
A-H(ST)HV   7x4x1,4 S Lg (H45) (M-SW) 5739500 536 28 980 230 290 145
A-H(ST)HV  10x4x1,4 S Lg (H45) (M-SW) 5739650 743 33 1320 314 340 170
A-H(St)HV  20x4x1,4 S Lg (H45) (M-SW) 5739700 1391 42 2270 573 430 215
A-H(St)HV  30x4x1,4 S Lg (H45) (M-SW) 5739800 2041 49 3070 795 490 245
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.