Print Icon

BayRail® Signalling cables, core-stranded, armoured, flame retardant, non corrosive, FRNC/LSOH

A-HHBH

...x1x1,4 acc. to Bayka standard, based on DB Dlk 1.013.102y


NT91_A-HHBH_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung10-Verlegung im Freien, UV-Schutz beachten!38-Querwasserdicht40-Geschirmt23-Halogenfrei24-Flammwidrig26-Raucharm46-Robust44-Nagetierschutz51-Verlegung -10

 


Standards

Bayka company standard BayRail®,
electrical properties based on Dlk 1.013.102y,
flame propagation according to DIN VDE 0472, part 804, test method C,
smoke density according to DIN VDE 0482, part 1034-2 (EN61034-2),
corrosivity of fire gases according to DIN VDE 0482, part 267-2-2 (EN 50267-2-2),
toxicity according to DIN VDE 0260, part 305 (EN50305), limit based on EN50306-1, 2 and 3 for hazard level: max. 5 (for insulation, inner sheath, outer sheath).

The cables are in compliance with EU LVD (Low Voltage Directive 2014/35/EU) and RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Conductor diameter mm 1.4
Conductor resistance Ω/km ≤ 11.9
Insulation resistance GΩxkm ≥ 10
Mutual capacitance at 800 Hz nF/km ≤ 120
Alternating voltage test 50 Hz
Core-core Veff
Core-screen Veff

2500
2500
Temperature ranges °C
During laying, installing
Before and after laying, installing

-10 to +60
-40 to +60

Integrated monitoring cores from 10x1 on

Application

Signalling cable, optimised for installation, transversally watertight, flame-retardant and rodent-proof for railway control centres and surveillance systems, etc., suitable for installation in open air, in the ground, in cable tray channels, and for laying in tunnels and buildings.

The cable is halogen-free, flame-retardant, and with low smoke density, and therefore suitable for installation in areas with special hazards caused by fire propagation.

VDE approved and system-tested sleeves and conduits are available for this cable.

Type Designation Codes

A outdoor cable
H conductor insulation, halogen-free
H inner sheath, halogen-free
B armouring, 2 layers, steel tape 0.1 or 0.2 mm
H outer sheath, halogen-free, frame-retardant
S signalling cable
LG stranded in layers

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-HHBH 7 x 1 x 1,4 S LG (H120)


Print Icon

BayRail® Signalling cables, core-stranded, armoured, flame retardant, non corrosive, FRNC/LSOH

A-HHBH

...x1x1,4 acc. to Bayka standard, based on DB Dlk 1.013.102y

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
A-HHBH       4x1x1,4 S (H 120) (M-SW) 5741400 62 15 300 30 115 150
A-HHBH       7x1x1,4 S (H 120) (M-SW) 5741360 108 17 405 53 130 170
A-HHBH      10x1x1,4 S (H 120) (M-SW) 5741361 154 19 490 76 145 190
A-HHBH      14x1x1,4 S (H 120) (M-SW) 5741362 220 20 575 107 150 200
A-HHBH      20x1x1,4 S (H 120) (M-SW) 5741353 312 22 725 153 165 220
A-HHBH      24x1x1,4 S (H 120) (M-SW) 5741354 374 24 880 184 180 240
A-HHBH      30x1x1,4 S (H 120) (M-SW) 5741355 466 25 1000 230 190 250
A-HHBH      40x1x1,4 S (H 120) (M-SW) 5741366 620 27 1250 307 210 280
A-HHBH      50x1x1,4 S (H 120) (M-SW) 5741357 774 30 1510 384 230 310
A-HHBH      60x1x1,4 S (H 120) (M-SW) 5741358 928 32 1710 461 240 320
A-HHBH      80x1x1,4 S (H 120) (M-SW) 5741380 1236 36 2170 615 270 360
A-HHBH     100x1x1,4 S (H 120) (M-SW) 5741359 1544 40 2600 769 300 400
A-HHBH     120x1x1,4 S (H 120) (M-SW) 5741390 1852 41 2980 923 310 420
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.