Print Icon

BayMotion® nonfire B2ca soilblack EMC
Acc. to CPR, UV- and weather resistant, direct buriable, oil resistant, flexible

B2ca soilblack VFD EMC 3+3

BayMotion® nonfire B2ca soilblack VFD EMC 3+3
acc. to IEC 60502-1 and Bayka company standard


IB192_soilblack VFD EMC 3+3_en
RoHS_LogoREACH_LogoCE_Logo27_BauPVO

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung16-Inhouse10-Verlegung im Freien, UV-Schutz beachten!20-UV-beständig23-Halogenfrei24-Flammwidrig26-Raucharm28-Ölbeständig42-Flexibel41-EMC+50-Verlegung -500_leerB2

 


Standards

IEC 60502-1, Bayka company standard

Cables acc. to CPR

Euroclass B2ca
Smoke production s1
Flaming droplets d2
Acidity a1

Flame retardant and self-extinguishing acc. to EN 60332-1-2,
halogen-free according to EN 60754-2,
fire behavior according to EN 50399,
smoke production according to EN 50399.

UV and weather resistance based on DIN EN 50289-4-17,
resistance to microorganisms (direct buriable) acc. to ISO 846,
ozone resistance acc. to DIN VDE 0276-604 (EN50396),
oil resistance acc. to EN 60811-404 70°C 168h.

The cables are in compliance with EU LVD (Low Voltage Directive) and RoHS Directive (Restriction of Hazardous Substances) and REACH (European Chemicals Regulation).

Technical Data

Conductor resistance
acc. to EN 60228 (DIN VDE 0295)
Conductor
class 5
Rated voltage U0/U kV 0,6/1
Testing voltage kV core/core 4
Cable temperature °C 
static laying (min)
occasionally moved (min)

-30
-5
Permissible operating temperature (conductor) °C
permanent installation (max)
occasionally moved (max)

+90
+90
Colours of cores acc. to HD 308/4
Performance conductor
Protective conductor

Brown, black, grey
Green-yellow

Application

BayMotion® nonfire B2ca soilblack VFD EMC 3+3 are HP-elastomer insulated, low capacitive and double shielded motor connection cables as energy, control, connection and connecting cables for drive systems (e.g. three-phase motors) with frequency Inverter technology.

Low mutual capacitance of the cores and the low-capacitance shielding allow a low-loss power transfer compared to PVC insulated wires. The optimized double-shielding facilitates a failure-free operation in EMC-sensitive surrondings. Minimization of conduction induced, high frequency engine mounting currents.

 

BayMotion® nonfire B2ca soilblack VFD EMC 3+3 are designed for:

  • laying in buildings with high fire-protection requirements
  • protection of persons and valuable capital goods
  • fix laying in dry and damp surroundings
  • outdoor laying by Bayka Soil Technology, UV and ozone resistant
  • directly buriable by Bayka Soil Technology, EN ISO approved
  • suitable for fixed installation with normal mechanical load, and for occasionally flexible use with free movement and without additional mechanical load

 

Designed for the following applications

  • Large Drives
  • Servo drive technologies
  • Automation and Control
  • Plastics and rubber industry
  • Machine tool building
  • Pharmaceutical and chemical industry
  • Paper- and heavy industries
  • Ventilating and air-conditioning systems

Order Example

BayMotion® nonfire B2ca Soilblack VFD EMC 3x150 + 3x25 0,6/1 kV


Print Icon

BayMotion® nonfire B2ca soilblack EMC
Acc. to CPR, UV- and weather resistant, direct buriable, oil resistant, flexible

B2ca soilblack VFD EMC 3+3

BayMotion® nonfire B2ca soilblack VFD EMC 3+3
acc. to IEC 60502-1 and Bayka company standard

Product Bayka Order No. Cu No. Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated
kg/km mm kg/km daN min. mm min. mm  
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x1,5+3x0,25 0,6/1 kV
6099514 91 14 302 8 90 225
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x2,5+ 3x0,5 0,6/1 kV
6099524 144 15 398 14 100 240
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x4  +3x0,75 0,6/1 kV
6099534 224 17 465 21 105 255
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x6  + 3x1   0,6/1 kV
6099544 298 18 615 32 110 270
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x10 + 3x1,5 0,6/1 kV
6099554 491 20 805 52 120 300
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x16 + 3x2,5 0,6/1 kV
6099564 723 22 1010 83 140 345
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x25 + 3x4   0,6/1 kV
6099574 1136 26 1315 131 160 390
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x35 + 3x6   0,6/1 kV
6099584 1535 29 1825 185 180 430
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x50 + 3x10  0,6/1 kV
6099294 2156 31 2315 270 185 465
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x70 + 3x10  0,6/1 kV
6099304 2871 33 3075 360 200 500
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x70 + 3x16  0,6/1 kV
6098304 2871 34 3075 645 210 525
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x95 + 3x16  0,6/1 kV
6099314 3953 38 4425 500 230 570
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x120 + 3x16 0,6/1 kV
6099324 4836 42 5425 612 250 630
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x120 + 3x25 0,6/1 kV
6098324 4982 43 5583 653 260 645
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x150 + 3x25 0,6/1 kV
6099334 5412 48 6074 788 290 720
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x185 + 3x25 0,6/1 kV
6099354 7077 51 7885 945 305 765
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x185 + 3x35 0,6/1 kV
6099364 7318 52 8643 990 310 780
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x240 + 3x35 0,6/1 kV
6099374 9015 57 10155 1238 340 855
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x240 + 3x50 0,6/1 kV
6099384 9075 58 10305 1305 355 885
BayMotion® nonfire B2ca
Soilblack VFD EMC 3x240+3x42,5 0,6/1 kV
6099414 9720 58 10785 1271 355 885
Errors and omissions excepted, weights and dimensions are approximate values.
Other designs, fitted lengths and larger delivery lengths on request.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding over a stencil and a cable temperature >30 ° C.
*) CPR Construction Products Regulation Class,
DoP Declaration of Performance.
The DoP applies exclusively to Bayka cables.