Download IconPrint Icon

BayCom® FO outdoor cables, metal-free, without armouring/rodent protection

A-DQ(ZN)2Y

blowing optimised acc. to DIN VDE and Bayka standard


PT202_A-DQ(ZN)2Y_verseilt_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung06-Einblasoptimiert20-UV-beständig36-Längswasserdicht51-Verlegung -10

 


Standards

DIN VDE 0888-114, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Single-mode fibre
G.652.D (Standard)
G.652.D (BayCom *)
G.657.A1

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
E9/125 0,36F3,5 0,21H18
Graded index fibre
OM2
OM3
OM4

G50/125 2,5B500 0,7F500
G50/125 2,5B1500 0,7F500
G50/125 2,5B3500 0,7F500
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage
laying
operation


-40 to +70
-10 to +60
-30 to +70

Application

Metal-free outdoor cable without rodent protection, as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:

  • Light-weight outdoor cable (optimised for blowing)
    Cable design, wall thicknesses and selected materials with optimised flexibility allow large blow in. Special HDPE compounds are insensitive to pressure and guarantee a rugged cable design in BayCom quality.
    The cable is also suitable for installation outdoors, in trays and ducts, on cable trays and pipes. For direct laying in the ground and large mechanical loads, additional protective measures must be provided.

The following applies to FO cables acc. to the company standard BayCom LWL01:

  • Quality assurance through VDE Certificate/VDE manufacturing report
  • 2 rip cords facilitate installation

The following applies additionally for BayCom* FO cables

Improved optical properties compared to standard fibres

Type Designation Codes

A outdoor cable
D loose tube, filled
Q cable core dry filled, longitudinally watertight
(ZN) non-metallic stress relief elements
2Y outer sheath made of polyethylene, PE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DQ(ZN)2Y 12x12 E9/125
A-DQ(ZN)2Y 12x12 E9/125 G.652.D BayCom*


Print Icon

BayCom® FO outdoor cables, metal-free, without armouring/rodent protection

A-DQ(ZN)2Y

blowing optimised acc. to DIN VDE and Bayka standard

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DQ(ZN)2Y         1x 2 E9/125  (VS) 5800011 2 9 65 150 140 190 2.5
A-DQ(ZN)2Y         2x 2 E9/125 5800021 4 9 65 150 140 190 2.5
A-DQ(ZN)2Y         4x 2 E9/125 5800031 8 9 65 150 140 190 2.5
A-DQ(ZN)2Y         6x 2 E9/125 5800041 12 10 75 150 150 200 2.5
A-DQ(ZN)2Y         6x 4 E9/125 5800051 24 10 75 150 150 200 2.5
A-DQ(ZN)2Y         6x 6 E9/125 5800061 36 10 75 150 150 200 2.5
A-DQ(ZN)2Y         4x12 E9/125 5800071 48 10 80 150 160 210 3.0
A-DQ(ZN)2Y         5x12 E9/125 5800081 60 10 80 150 160 210 3.0
A-DQ(ZN)2Y         6x12 E9/125 5800091 72 11 90 150 170 220 3.0
A-DQ(ZN)2Y         8x12 E9/125 5800101 96 12 110 150 190 250 4.0
A-DQ(ZN)2Y        10x12 E9/125 5800111 120 14 140 150 210 270 5.0
A-DQ(ZN)2Y        12x12 E9/125 5800121 144 15 170 200 230 300 6.0
A-DQ(ZN)2Y        16x12 E9/125 5800131 192 18 240 250 270 360 9.0
A-DQ(ZN)2Y        24x12 E9/125 5800141 288 18 220 250 265 350 7.5
The part numbers in the table are for fibers after G.652.D (standard)
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.