Download IconPrint Icon

BayCom® FO outdoor cables, metal-free, with armouring/rodent protection

A-DQ(ZN)b2Y

blowing optimised acc. to DIN VDE and Bayka standard


PT222_A-DQ(ZN)b2Y_verseilt_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

08-Trogverlegung04-Rohrverlegung06-Einblasoptimiert20-UV-beständig44-Nagetierschutz36-Längswasserdicht51-Verlegung -10

 


Standards

DIN VDE 0888-114, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Single-mode fibre
G.652.D (Standard)
G.652.D (BayCom *)
G.657.A1

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
E9/125 0,36F3,5 0,21H18
Graded index fibre
OM2
OM3
OM4

G50/125 2,5B500 0,7F500
G50/125 2,5B1500 0,7F500
G50/125 2,5B3500 0,7F500
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage
laying
operation


-40 to +70
-10 to +60
-30 to +70

Application

Metal-free outdoor cable with non-metallic rodent protection, as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:

  • Light-weight outdoor cable (optimised for blowing)
    Cable design, wall thicknesses and selected materials with optimised flexibility allow large blow in. Special HDPE compounds are insensitive to pressure and guarantee a rugged cable design in BayCom quality.
    The cable is also suitable for installation outdoors, in trays and ducts, on cable trays and pipes. For direct laying in the ground and large mechanical loads, additional protective measures must be provided.

The following applies to FO cables acc. to the company standard BayCom LWL01:

  • Quality assurance through VDE Certificate/VDE manufacturing report
  • 2 rip cords facilitate installation

The following applies additionally for BayCom* FO cables

Improved optical properties compared to standard fibres

Type Designation Codes

A outdoor cable
D loose tube, filled
Q cable core dry filled, longitudinally watertight
(ZN) non-metallic stress relief elements
b non-metallic rodent protection
2Y outer sheath made of polyethylene, PE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DQ(ZNb)2Y 12x12 E9/125
A-DQ(ZNb)2Y 12x12 E9/125 G.652.D BayCom*


Print Icon

BayCom® FO outdoor cables, metal-free, with armouring/rodent protection

A-DQ(ZN)b2Y

blowing optimised acc. to DIN VDE and Bayka standard

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DQ(ZN)b2Y        1x 2 E9/125  (VS) 5800411 2 10 68 250 150 200 2.5
A-DQ(ZN)b2Y        1x 4 E9/125  (VS) 5800531 4 10 68 250 150 200 2.5
A-DQ(ZN)b2Y        2x 2 E9/125 5800421 4 10 69 250 150 200 2.5
A-DQ(ZN)b2Y        1x 6 E9/125  (VS) 5800541 6 10 68 250 150 200 2.5
A-DQ(ZN)b2Y        3x 2 E9/125 5800791 6 10 69 250 150 200 2.5
A-DQ(ZN)b2Y        1x 8 E9/125  (VS) 5801791 8 10 81 250 165 220 3.0
A-DQ(ZN)b2Y        2x 4 E9/125 5800761 8 10 69 250 150 200 2.5
A-DQ(ZN)b2Y        4x 2 E9/125 5800431 8 10 70 250 150 200 2.5
A-DQ(ZN)b2Y        1x10 E9/125  (VS) 5801801 10 10 80 250 165 220 3.0
A-DQ(ZN)b2Y        1x12 E9/125  (VS) 5800191 12 10 80 250 165 220 3.0
A-DQ(ZN)b2Y        2x 6 E9/125 5800751 12 10 69 250 150 200 2.5
A-DQ(ZN)b2Y        3x 4 E9/125 5800801 12 10 70 250 150 200 2.5
A-DQ(ZN)b2Y        6x 2 E9/125 5800441 12 10 80 250 160 210 2.5
A-DQ(ZN)b2Y        2x 8 E9/125 5800771 16 10 80 250 165 220 3.0
A-DQ(ZN)b2Y        4x 4 E9/125 5800841 16 10 70 250 150 200 2.5
A-DQ(ZN)b2Y        3x 6 E9/125 5800811 18 10 70 250 150 200 2.5
A-DQ(ZN)b2Y        2x10 E9/125 5800781 20 10 80 250 160 210 3.0
A-DQ(ZN)b2Y        2x12 E9/125 5800241 24 10 80 250 165 220 3.0
A-DQ(ZN)b2Y        3x 8 E9/125 5800821 24 10 81 250 165 220 3.0
A-DQ(ZN)b2Y        4x 6 E9/125 5800851 24 10 70 250 150 200 2.5
A-DQ(ZN)b2Y        6x 4 E9/125 5800251 24 10 80 250 160 210 2.5
A-DQ(ZN)b2Y        3x10 E9/125 5800831 30 10 81 250 165 220 3.0
A-DQ(ZN)b2Y        4x 8 E9/125 5800861 32 10 82 250 165 220 3.0
A-DQ(ZN)b2Y        3x12 E9/125 5800231 36 10 82 250 165 220 3.0
A-DQ(ZN)b2Y        6x 6 E9/125 5800451 36 10 80 250 160 210 2.5
A-DQ(ZN)b2Y        4x10 E9/125 5800881 40 10 82 250 165 220 3.0
A-DQ(ZN)b2Y        4x12 E9/125 5800211 48 10 83 250 165 220 3.0
A-DQ(ZN)b2Y        5x12 E9/125 5800281 60 10 84 250 165 220 3.0
A-DQ(ZN)b2Y        6x10 E9/125 5800581 60 11 97 250 170 220 3.0
A-DQ(ZN)b2Y        6x12 E9/125 5800461 72 11 98 250 170 220 3.0
A-DQ(ZN)b2Y        8x12 E9/125 5800471 96 12 125 250 195 260 4.0
A-DQ(ZN)b2Y       10x12 E9/125 5800481 120 14 152 250 210 280 5.0
A-DQ(ZN)b2Y       12x12 E9/125 5800291 144 15 183 300 230 310 6.0
A-DQ(ZN)b2Y       16x12 E9/125 5800491 192 18 258 400 270 360 9.0
A-DQ(ZN)b2Y       24x12 E9/125 5800501 288 18 240 350 270 360 7.5
The part numbers in the table are for fibers after G.652.D (standard)
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.