Download IconPrint Icon

BayCom® FO outdoor cables, metal-free, with armouring/rodent protection

A-DF(ZN)b2Y

direct burial acc. to DIN VDE and Bayka standard


PT322_A-DF(ZN)b2Y_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung20-UV-beständig46-Robust44-Nagetierschutz36-Längswasserdicht51-Verlegung -10

 


Standards

DIN VDE 0888-3, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Single-mode fibre
G.652.D (Standard)
G.652.D (BayCom *)
G.657.A1

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
E9/125 0,36F3,5 0,21H18
Graded index fibre
OM2
OM3
OM4

G50/125 2,5B500 0,7F500
G50/125 2,5B1500 0,7F500
G50/125 2,5B3500 0,7F500
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage
laying
operation


-40 to +70
-10 to +60
-30 to +70

Application

Metal-free outdoor cable with non-metallic rodent protection, as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:

  • Rugged outdoor cable (direct underground installation)
    This cable is optimised for underground installation and complies with the long experience of fibre optic and telecommunication cables laid in the ground (VDE 0888, VDE 0816 and similar).

The following applies to FO cables acc. to the company standard BayCom LWL01:

  • Quality assurance through VDE Certificate/VDE manufacturing report
  • 2 rip cords facilitate installation

The following applies additionally for BayCom* FO cables

Improved optical properties compared to standard fibres

Type Designation Codes

A outdoor cable
D loose tube, filled
F cable core filled with petroleum jelly, longitudinally watertight
(ZN) non-metallic stress relief elements
b non-metallic rodent protection
2Y outer sheath made of polyethylene, PE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DF(ZN)b2Y 12x12 E9/125
A-DF(ZN)b2Y 12x12 E9/125 G.652.D BayCom*


Print Icon

BayCom® FO outdoor cables, metal-free, with armouring/rodent protection

A-DF(ZN)b2Y

direct burial acc. to DIN VDE and Bayka standard

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DF(ZN)b2Y        1x 2 E9/125  (VS) 5801210 2 11 95 250 170 220 3.5
A-DF(ZN)b2Y        2x 2 E9/125 5801220 4 11 95 250 170 220 3.5
A-DF(ZN)b2Y        4x 2 E9/125 5801230 8 11 95 250 170 220 3.5
A-DF(ZN)b2Y        6x 2 E9/125 5801240 12 12 105 250 180 240 4.0
A-DF(ZN)b2Y        6x 4 E9/125 5801250 24 12 105 250 180 240 4.0
A-DF(ZN)b2Y        6x 6 E9/125 5801260 36 12 105 250 180 240 4.0
A-DF(ZN)b2Y        4x12 E9/125 5801270 48 12 108 250 180 240 4.0
A-DF(ZN)b2Y        5x12 E9/125 5801280 60 12 108 250 180 240 4.0
A-DF(ZN)b2Y        6x12 E9/125 5801290 72 13 125 250 190 250 4.5
A-DF(ZN)b2Y        8x12 E9/125 5801300 96 14 155 250 210 280 5.5
A-DF(ZN)b2Y       10x12 E9/125 5801310 120 15 185 300 230 310 6.5
A-DF(ZN)b2Y       12x12 E9/125 5801320 144 17 225 350 260 340 8.0
A-DF(ZN)b2Y       16x12 E9/125 5801330 192 20 300 450 300 390 11.0
A-DF(ZN)b2Y       24x12 E9/125 5801340 288 19 300 450 300 390 10.0
The part numbers in the table are for fibers after G.652.D (standard)
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.