BayCom® FO outdoor cables, metal-free, without armouring/rodent protection

A-DQ(ZN)2Y

direct burial acc. to DIN VDE and Bayka standard


PT202_A-DQ(ZN)2Y_verseilt_en
VDE_LogoRoHS_LogoREACH_LogoCE_Logo

 

02-Erdverlegung08-Trogverlegung04-Rohrverlegung20-UV-beständig46-Robust36-Längswasserdicht51-Verlegung -10

 


Standards

DIN VDE 0888-114, EN 60794-3 (VDE 0888-108),
ITU-T G.652.D, ITU-T G.651, ITU-T G.657 A1,
BayCom LWL01.

The cables are in compliance with RoHS Directive EU 2002/65/EC - RoHS 2.0 and Regulation No. 1907/2006 (REACH).

Technical Data

Single-mode fibre
G.652.D (Standard)
G.652.D (BayCom *)
G.657.A1

E9/125 0,36F3,5 0,22H18
E9/125 0,35F3,0 0,21H18
E9/125 0,36F3,5 0,21H18
Graded index fibre
OM2
OM3
OM4

G50/125 2,5B500 0,7F500
G50/125 2,5B1500 0,7F500
G50/125 2,5B3500 0,7F500
Colour coding of fibres acc. to IEC 60304
Permissible temperature range °C
transport and storage
laying
operation


-40 to +70
-10 to +60
-30 to +70

Application

Metal-free outdoor cable without rodent protection, as termination and connection cable in wide area and local area networks, PBXs, for telephony and data transmission in the design:

  • Rugged outdoor cable (direct underground installation)
    This cable is optimised for underground installation and complies with the long experience of fibre optic and telecommunication cables laid in the ground (VDE 0888, VDE 0816 and similar).

The following applies to FO cables acc. to the company standard BayCom LWL01:

  • Quality assurance through VDE Certificate/VDE manufacturing report
  • 2 rip cords facilitate installation

The following applies additionally for BayCom* FO cables

Improved optical properties compared to standard fibres

Type Designation Codes

A outdoor cable
D loose tube, filled
Q cable core dry filled, longitudinally watertight
(ZN) non-metallic stress relief elements
2Y outer sheath made of polyethylene, PE

Special Designs

Design according to national and international standards
Design according to customer specifications
Design with limited tolerance of outer diameter on request

Order Example

A-DQ(ZN)2Y 12x12 E9/125
A-DQ(ZN)2Y 12x12 E9/125 G.652.D BayCom*


Print Icon

BayCom® FO outdoor cables, metal-free, without armouring/rodent protection

A-DQ(ZN)2Y

direct burial acc. to DIN VDE and Bayka standard

Product Bayka Order No. No. of fibers Outer ∅
approx.
Net weight
approx.
Max. tensile force Bending radius one-off Bending radius repeated Fire load
mm kg/km daN min. mm min. mm MJ/m  
A-DQ(ZN)2Y         1x 2 E9/125  (VS) 5800010 2 11 85 150 170 220 3.5
A-DQ(ZN)2Y         2x 2 E9/125 5800020 4 11 85 150 170 220 3.5
A-DQ(ZN)2Y         4x 2 E9/125 5800030 8 11 85 150 170 220 3.5
A-DQ(ZN)2Y         6x 2 E9/125 5800040 12 11 95 150 180 230 4.0
A-DQ(ZN)2Y         6x 4 E9/125 5800050 24 11 97 150 180 230 4.0
A-DQ(ZN)2Y         6x 6 E9/125 5800060 36 11 97 150 180 230 3.5
A-DQ(ZN)2Y         4x12 E9/125 5800070 48 12 101 150 180 240 4.0
A-DQ(ZN)2Y         5x12 E9/125 5800080 60 12 101 150 180 240 4.0
A-DQ(ZN)2Y         6x12 E9/125 5800090 72 12 115 200 190 250 4.5
A-DQ(ZN)2Y         8x12 E9/125 5800100 96 13 140 250 210 280 5.0
A-DQ(ZN)2Y        10x12 E9/125 5800110 120 15 170 300 230 300 6.0
A-DQ(ZN)2Y        12x12 E9/125 5800120 144 16 205 300 255 340 7.5
A-DQ(ZN)2Y        16x12 E9/125 5800130 192 19 280 400 290 390 11.0
A-DQ(ZN)2Y        24x12 E9/125 5800140 288 19 260 400 290 390 9.5
The part numbers in the table are for fibers after G.652.D (standard)
For other fibers supplement the cable designation with G.652.D BayCom*, G.657 A1, OM2, OM3, OM4 respectively.
Errors and omissions excepted, weights and dimensions are approximate values.
Tensile force only valid when cable sheath and cable core involved.
The bending radius one-off is for professionally installed cables, unique molding.
The bending radius repeated applies to dynamic bending operations eg during the installation.
Other designs, fitted lengths and larger delivery lengths on request.